CoChat

Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope

Rudolph, C., Schneider, J. P., Wallenborn, J., Schaffranietz, L. · 2005 · Anaesthesia
Cited by 88

The DOI matches its Crossref record.

Abstract

Summary: The movements of the upper cervical spine were measured by fluoroscopy in 20 patients during laryngoscopy with the Bonfils intubation fibrescope and the Macintosh laryngoscope. Laryngoscopy with both the Bonfils intubation fibrescope and the Macintosh laryngoscope resulted in significant extension of the cervical spine as compared to the neutral position but this extension was significantly less with the Bonfils intubation fibrescope than with the Macintosh (p = 0.001). However, the atlanto‐occipital distance was significantly greater during laryngoscopy with the Bonfils intubation fibrescope (p = 0.002), and the angle between the occiput and C1 differed significantly between the two techniques (p = 0.001). With the Bonfils intubation fibrescope, significantly less extension was also found at the C1/C2 and C3/C4 levels (p = 0.001 and p = 0.049, respectively). There is therefore significantly less movement of the upper cervical spine during laryngoscopy with the Bonfils fibrescope compared with the Macintosh laryngoscope.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2044.2005.04224.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Rudolph, C., Schneider, J. P., Wallenborn, J., & Schaffranietz, L.
Venue
Anaesthesia
Publisher
Wiley
Published
2005-06-16
Volume
60
Issue
7
Pages
668-672
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W2020156313
Cited by
88
References
0
FWCI
6.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.