The DOI matches its Crossref record.
Cervical Spine Motion During Tracheal Intubation with Manual In-Line Stabilization: Direct Laryngoscopy versus GlideScope® Videolaryngoscopy
Abstract
BACKGROUND: The optimal tracheal intubation technique for patients with potential cervical (C) spine injury remains controversial. Using continuous cinefluoroscopy, we conducted a prospective study comparing C-spine movement during intubation using direct laryngoscopy (DL) or GlideScope videolaryngoscopy (GVL), with uninterrupted manual in-line stabilization of the head by an assistant. METHODS: Twenty patients without C-spine pathology were studied. After induction of general anesthesia with neuromuscular blockade, both DL and GVL were performed on every patient in random order. Cinefluoroscopic images of C-spine movement during GVL and DL were acquired and divided into four stages: a baseline image before airway manipulation, glottic visualization, insertion of the endotracheal tube into the glottis, and tracheal intubation. Peak segmental motion from the occiput to C5 was measured offline for each patient and each stage, averages were calculated, and movements induced by each instrument were compared using a two-way ANOVA. Also studied were the proportion of patients with occiput-C1 rotation exceeding 10, 15, or 20 degrees, and the quality of glottic visualization. RESULTS: No significant difference was found between DL and GVL regarding average segmental spine movement at any level (P values between 0.22 and 0.70). During both techniques, motion was mainly an extension concentrated in the rostral C-spine and occurred predominantly during glottic visualization. The proportion of patients with occiput-C1 extension of more than 10, 15, or 20 degrees was not significantly different. Glottic visualization was significantly better with GVL compared with DL. CONCLUSION: During intubation under general anesthesia with neuromuscular blockade and manual in-line stabilization, the use of GVL produced better glottic visualization, but did not significantly decrease movement of the nonpathologic C-spine when compared with DL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Updated by the Committee on Standards and Practice Parameters, Apfelbaum, J. L., Hagberg, C. A., Caplan, R. A., Blitt, C. D., Connis, R. T., Nickinovich, D. G., Hagberg, C. A., The previous update was developed by the American Society of Anesthesiologists Task Force on Difficult Airway Management, Caplan, R. A., et al. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31827773b2 · Cited by 2,559
Aziz, M. F., Healy, D., Kheterpal, S., Fu, R. F., Dillman, D., & Brambrink, A. M. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182023eb7 · Cited by 395
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Griesdale, D. E. G., Liu, D., McKinney, J., & Choi, P. T. (2012) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-011-9620-5 · Cited by 363
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., Schofield-Robinson, O. J., & Smith, A. F. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex228 · Cited by 359
Metadata
- Authors
- Robitaille, A., Williams, S. R., Tremblay, M.-H., Guilbert, F., Thériault, M., & Drolet, P.
- Venue
- Anesthesia & Analgesia
- Published
- 2008-03
- Volume
- 106
- Issue
- 3
- Pages
- 935-941
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2084615897
- Cited by
- 191
- References
- 0
- FWCI
- 21.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cervical Spine Motion During Tracheal Intubation with Manual In-Line Stabilization: Direct Laryngoscopy versus GlideScope® Videolaryngoscopy. https://app.cochat.ai/papers/10.1213/ane.0b013e318161769e
- The paper
- Robitaille, A., Williams, S. R., Tremblay, M.-H., Guilbert, F., Thériault, M., & Drolet, P. (2008). Cervical Spine Motion During Tracheal Intubation with Manual In-Line Stabilization: Direct Laryngoscopy versus GlideScope® Videolaryngoscopy. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e318161769e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.