The DOI matches its Crossref record.
A quantitative review and meta‐analysis of performance of non‐standard laryngoscopes and rigid fibreoptic intubation aids
Abstract
Summary: This quantitative review summarises studies of rigid fibreoptic laryngoscopy systems. In 6622 ‘normal’ patients only the Bonfils and CTrach had homogenous data and first time intubation success rates above 90%. In 1110 patients predicted or known to be difficult to intubate only the Bonfils, CTrach and Glidescope had homogenous data and first‐time success rates above 90%. In comparative studies with the Macintosh‐3 blade, no device had homogenous data in more than one study. Many devices had higher summed performances, but due to data heterogeneity, interpretation is very difficult, if worthwhile at all. The currently available data do not provide strong evidence that these devices should supersede standard direct laryngoscopy for routine or difficult intubation. Further research needs to be of high quality, studying relevant patients to create such evidence. Multicentre collaborations are likely to be needed studying known difficult patients or creating databases reporting the success/failure rate of these devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
Self-citationAziz, M. F., Healy, D., Kheterpal, S., Fu, R. F., Dillman, D., & Brambrink, A. M. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182023eb7 · Cited by 395
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Self-citationGriesdale, D. E. G., Liu, D., McKinney, J., & Choi, P. T. (2012) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-011-9620-5 · Cited by 363
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Metadata
- Authors
- Mihai, R., Blair, E., Kay, H., & Cook, T. M.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2008-06-10
- Volume
- 63
- Issue
- 7
- Pages
- 745-760
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1535762044
- Cited by
- 179
- References
- 0
- FWCI
- 24.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A quantitative review and meta‐analysis of performance of non‐standard laryngoscopes and rigid fibreoptic intubation aids. https://app.cochat.ai/papers/10.1111/j.1365-2044.2008.05489.x
- The paper
- Mihai, R., Blair, E., Kay, H., & Cook, T. M. (2008). A quantitative review and meta‐analysis of performance of non‐standard laryngoscopes and rigid fibreoptic intubation aids. Anaesthesia. https://doi.org/10.1111/j.1365-2044.2008.05489.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.