Global oximetry: an international anaesthesia quality improvement project
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: Pulse oximetry is mandatory during anaesthesia in many countries, a standard endorsed by the World Health Organization ‘Safe Surgery Saves Lives’ initiative. The Association of Anaesthetists of Great Britain and Ireland, the World Federation of Societies of Anaesthesiologists and GE Healthcare collaborated in a quality improvement project over a 15‐month period to investigate pulse oximetry in four pilot sites in Uganda, Vietnam, India and the Philippines, using 84 donated pulse oximeters. A substantial gap in oximeter provision was demonstrated at the start of the project. Formal training was essential for oximeter‐naïve practitioners. After introduction of oximeters, logbook data were collected from over 8000 anaesthetics, and responses to desaturation were judged appropriate. Anaesthesia providers believed pulse oximeters were essential for patient safety and defined characteristics of the ideal oximeter for their setting. Robust systems for supply and maintenance of low‐cost oximeters are required for sustained uptake of pulse oximetry in low‐ and middle‐income countries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A surgical safety checklist to reduce morbidity and mortality in a global population
Haynes, A. B., Weiser, T. G., Berry, W. R., Lipsitz, S. R., Breizat, A.-H. S., Dellinger, E. P., Herbosa, T., Joseph, S., Kibatala, P. L., Lapitan, M. C. M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0810119 · Cited by 5,688
Self-citationAn estimation of the global volume of surgery: a modelling strategy based on available data
Weiser, T. G., Regenbogen, S. E., Thompson, K. D., Haynes, A. B., Lipsitz, S. R., Berry, W. R., & Gawande, A. A. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60878-8 · Cited by 2,511
Cited by
(2014) · Tropical Medicine & International Health · doi:10.1111/tmi.12313_2 · Cited by 543
Global operating theatre distribution and pulse oximetry supply: an estimation from reported data
Funk, L. M., Weiser, T. G., Berry, W. R., Lipsitz, S. R., Merry, A. F., Enright, A. C., Wilson, I. H., Dziekan, G., & Gawande, A. A. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60392-3 · Cited by 397
Self-citationThe Helsinki Declaration on Patient Safety in Anaesthesiology
Mellin-Olsen, J., Staender, S., Whitaker, D. K., & Smith, A. F. (2010) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32833b1adf · Cited by 389
Self-citationRecommendations for sepsis management in resource-limited settings
Dünser, M. W., Festic, E., Dondorp, A., Kissoon, N., Ganbat, T., Kwizera, A., Haniffa, R., Baker, T., Schultz, M. J., & Global Intensive Care Working Group of the European Society of Intensive Care Medicine (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2468-5 · Cited by 176
Aveling, E.-L., McCulloch, P., & Dixon-Woods, M. (2013) · BMJ Open · doi:10.1136/bmjopen-2013-003039 · Cited by 152
Metadata
- Authors
- Walker, I. A., Merry, A. F., Wilson, I. H., McHugh, G. A., O’Sullivan, E., Thoms, G. M., Nuevo, F., Whitaker, D. K., & on behalf of the GO Project teams
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2009-09-02
- Volume
- 64
- Issue
- 10
- Pages
- 1051-1060
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2031161568
- Cited by
- 67
- References
- 2
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.