CoChat

Global oximetry: an international anaesthesia quality improvement project

Open access
Walker, I. A., Merry, A. F., Wilson, I. H., McHugh, G. A., O’Sullivan, E., Thoms, G. M., Nuevo, F., Whitaker, D. K., on behalf of the GO Project teams · 2009 · Anaesthesia
Cited by 67

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Summary: Pulse oximetry is mandatory during anaesthesia in many countries, a standard endorsed by the World Health Organization ‘Safe Surgery Saves Lives’ initiative. The Association of Anaesthetists of Great Britain and Ireland, the World Federation of Societies of Anaesthesiologists and GE Healthcare collaborated in a quality improvement project over a 15‐month period to investigate pulse oximetry in four pilot sites in Uganda, Vietnam, India and the Philippines, using 84 donated pulse oximeters. A substantial gap in oximeter provision was demonstrated at the start of the project. Formal training was essential for oximeter‐naïve practitioners. After introduction of oximeters, logbook data were collected from over 8000 anaesthetics, and responses to desaturation were judged appropriate. Anaesthesia providers believed pulse oximeters were essential for patient safety and defined characteristics of the ideal oximeter for their setting. Robust systems for supply and maintenance of low‐cost oximeters are required for sustained uptake of pulse oximetry in low‐ and middle‐income countries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2044.2009.06067.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 67

Metadata

Authors
Walker, I. A., Merry, A. F., Wilson, I. H., McHugh, G. A., O’Sullivan, E., Thoms, G. M., Nuevo, F., Whitaker, D. K., & on behalf of the GO Project teams
Venue
Anaesthesia
Publisher
Wiley
Published
2009-09-02
Volume
64
Issue
10
Pages
1051-1060
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W2031161568
Cited by
67
References
2
FWCI
8.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.