The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Inhibition of activated protein C and its cofactor protein S by antiphospholipid antibodies
Abstract
S ummary. We have investigated the effects of purified IgG fractions from plasma containing the lupus anticoagulant (LAC) and/or IgG anticardiolipin antibody (ACA) on the degradation of factor Va by an activated protein C‐protein S complex. Plasma samples from 10 patients were studied. LAC was detected by a Russell's Viper venom technique. ACA was determined by ELISA. IgG fractions were obtained from each plasma sample by protein A‐Sepharose fractionation. This fraction was shown to exhibit ACAILAC activity. Using purified activated protein C (APC), protein S and phosphati‐dylserine/phosphatidylcholine, factor Va degradation was assessed in the presence and absence of IgG fractions from LAC/ACA containing plasmas. After 2 min incubation the mean factor Va degradation by APC and protein S in the presence of IgG LAC/ACA fractions was 14% compared with 52% with normal IgG. A similar effect was seen when phospholipid was substituted by washed freeze‐thawed platelets. Experiments employing varying concentrations of protein S and phospholipid revealed marked differences in respect of the inhibitory specificity of the different antiphospholipid antibodies. These results indicate that antiphospholipid antibodies have an inhibitory effect on the activated protein C/protein S complex and provide some explanation for a relationship between antiphospholipid antibodies and thrombosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boey, M. L., Colaco, C. B., Gharavi, A. E., Elkon, K. B., Loizou, S., & Hughes, G. R. (1983) · BMJ · doi:10.1136/bmj.287.6398.1021 · Cited by 508
Cited by
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740
Self-citationIncreased fetal loss in women with heritable thrombophilia
Preston, F., Rosendaal, F., Walker, I., Briët, E., Berntorp, E., Conard, J., Fontcuberta, J., Makris, M., Mariani, G., Noteboom, W., et al. (1996) · The Lancet · doi:10.1016/s0140-6736(96)04125-6 · Cited by 661
Self-citationOosting, J., Derksen, R., Bobbink, I., Hackeng, T., Bouma, B., & de Groot, P. (1993) · Blood · doi:10.1182/blood.v81.10.2618.2618 · Cited by 488
Pierangeli, S. S., Colden-Stanfield, M., Liu, X., Barker, J. H., Anderson, G. L., & Harris, E. N. (1999) · Circulation · doi:10.1161/01.cir.99.15.1997 · Cited by 325
Antiphospholipid antibodies and thrombosis
Greaves, M. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10362-8 · Cited by 309
Self-citation
Metadata
- Authors
- Malia, R. G., Kitchen, S., Greaves, M., & Preston, F. E.
- Venue
- British Journal of Haematology
- Publisher
- Wiley
- Published
- 1990-09
- Volume
- 76
- Issue
- 1
- Pages
- 101-107
- ISSN
- 0007-1048 (ISSN-L)
- 1365-2141
- OpenAlex
- W2017687893
- Cited by
- 209
- References
- 1
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inhibition of activated protein C and its cofactor protein S by antiphospholipid antibodies. https://app.cochat.ai/papers/10.1111/j.1365-2141.1990.tb07843.x
- The paper
- Malia, R. G., Kitchen, S., Greaves, M., & Preston, F. E. (1990). Inhibition of activated protein C and its cofactor protein S by antiphospholipid antibodies. British Journal of Haematology. https://doi.org/10.1111/j.1365-2141.1990.tb07843.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.