Optimization of the dilute prothrombin time for the detection of the lupus anticoagulant by use of a recombinant tissue thromboplastin
The DOI matches its Crossref record.
Abstract
Summary: The dilute prothrombin time (dPT) is a widely accepted sensitive screening test for the lupus anticoagulant (LA). In general, Simplastin (Organon Teknika), a rabbit brain thromboplastin, diluted 1/500, is used in this test. Recently, human tissue thromboplastin obtained by recombinant DNA technology has become available and we have evaluated the usefulness of one such preparation, Innovin (Dade), for the detection of the LA. dPTs, using several dilutions of Innovin were determined on plasmas from 18 normal individuals and 15 patients with a well‐documented LA. The dPT ratios, calculated as the individual result divided by the mean normal, were statistically compared. Innovin in dilutions from 1/100 onwards was found to be significantly more responsive to the LA than Simplastin (P < 0.05). Intraassay coefficients of variation (CVs) ranged from 1.05% to 14.8% with Innovin, versus 2.7%‐24.3% with Simplastin (P < 0.05); inter‐assay CVs ranged from 5.6%‐11.8% with Innovin, versus 4.2%‐33.8% with Simplastin (P < 0.001). Analysis of 316 consecutive plasma samples from nonanticoagulated patients, on which a LA determination was requested, showed a 100% sensitivity and a 96% specificity of the dPT performed with Innovin, as compared to 81% and 93% respectively for the dPT using Simplastin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740
Guidelines On The Investigation and Management Of The Antiphospholipid Syndrome
Greaves, M., Cohen, H., Machin, S. J., & Mackie, I. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.02069.x · Cited by 294
Galli, M., Borrelli, G., Jacobsen, E. M., Marfisi, R. M., Finazzi, G., Marchioli, R., Wisloff, F., Marziali, S., Morboeuf, O., & Barbui, T. (2007) · Blood · doi:10.1182/blood-2007-01-066043 · Cited by 170
“In essence, this is a prothrombin time-based assay performed with diluted thromboplastin: according to the type of reagent, the DPT is highly sensitive and specific for the presence of LA (29), caused by both aβ2GPI (30, 31) and aPT antibodies (31).”
MethodLaboratory Testing for Lupus Anticoagulants: A Review of Issues Affecting Results
Tripodi, A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.089524 · Cited by 81
Laboratory diagnosis of the antiphospholipid syndrome: a plethora of obstacles to overcome
Devreese, K., & Hoylaerts, M. F. (2009) · European Journal Of Haematology · doi:10.1111/j.1600-0609.2009.01243.x · Cited by 78
Metadata
- Authors
- Arnout, J., Vanrusselt, M., Huybrechts, E., & Vermylen, J.
- Venue
- British Journal of Haematology
- Publisher
- Wiley
- Published
- 1994-05
- Volume
- 87
- Issue
- 1
- Pages
- 94-99
- ISSN
- 0007-1048 (ISSN-L)
- 1365-2141
- OpenAlex
- W1992650827
- Cited by
- 67
- References
- 0
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of the dilute prothrombin time for the detection of the lupus anticoagulant by use of a recombinant tissue thromboplastin. https://app.cochat.ai/papers/10.1111/j.1365-2141.1994.tb04876.x
- The paper
- Arnout, J., Vanrusselt, M., Huybrechts, E., & Vermylen, J. (1994). Optimization of the dilute prothrombin time for the detection of the lupus anticoagulant by use of a recombinant tissue thromboplastin. British Journal of Haematology. https://doi.org/10.1111/j.1365-2141.1994.tb04876.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.