Elevated endogenous thrombin potential is associated with an increased risk of a first deep venous thrombosis but not with the risk of recurrence
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Summary: Measurement of the thrombin generating potential could provide a method for quantifying the composite effect of multiple risk factors. This study assessed the risk of a first as well as a recurrent venous thrombotic event associated with an increased endogenous thrombin potential (ETP). Analyses were performed in 360 patients and 404 control subjects of the Leiden Thrombophilia Study. The ETP was measured directly using a fluorogenic assay (Thrombinoscope TM). Individuals with an increased ETP, i.e. above 90th percentile measured in control subjects (>2109·0 nM·min) had a 1·5‐fold [95% confidence interval (CI): 0·9–2·3] increased risk of a first deep venous thrombosis. The risk was more pronounced after the analysis was restricted to idiopathic thromboses, i.e. 1·7‐fold (95% CI: 1·0–2·8). Overall, the hazard ratio of a recurrent thrombotic event associated with a high ETP, adjusted for age, sex and oral anticoagulant use was 1·1 (95% CI: 0·5–2·2). Thus, a high ETP was not associated with an increased relative risk of recurrent venous thrombosis. At present, the clinical relevance of the thrombin generation assay in predicting recurrent venous thrombosis remains uncertain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High plasma levels of factor VIII and the risk of recurrent venous thromboembolism
Kyrle, P. A., Minar, E., Hirschl, M., Bialonczyk, C., Stain, M., Schneider, B., Weltermann, A., Speiser, W., Lechner, K., & Eichinger, S. (2000) · New England Journal of Medicine · doi:10.1056/nejm200008173430702 · Cited by 763 · cited 1×
“…by (Ho et al, 2006), elevated TAFI levels (Eichinger et al, 2004), low vitamin B6 (Eichinger, 2006), low free TFPI (Hoke et al, 2005), hyperhomocysteinemia (Keijzer et al, 2002; Eichinger, 2003) and elevated levels of factor VIII and IX (Kyrle et al, 2000; Weltermann et al, 2003; Bobrow, 2005).”
BackgroundBaglin, T., Luddington, R., Brown, K., & Baglin, C. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14111-6 · Cited by 694
Self-citationd -Dimer Testing to Determine the Duration of Anticoagulation Therapy
Palareti, G., Cosmi, B., Legnani, C., Tosetto, A., Brusi, C., Iorio, A., Pengo, V., Ghirarduzzi, A., Pattacini, C., Testa, S., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054444 · Cited by 622 · cited 1×
“Palareti et al (2006) demonstrated that D-dimer testing could be used in the identification of individuals less prone to recurrent venous thrombosis.”
BackgroundRecurrent Venous Thromboembolism After Deep Vein Thrombosis: Incidence and Risk Factors
Hansson, P.-O., Sörbo, J., & Eriksson, H. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.6.769 · Cited by 590
Cited by
Wolberg, A. S., Rosendaal, F. R., Weitz, J. I., Jaffer, I. H., Agnelli, G., Baglin, T., & Mackman, N. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.6 · Cited by 369
Self-citationThrombin Generation Assay and Its Application in the Clinical Laboratory
Tripodi, A. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.248625 · Cited by 318
Interspecies differences in coagulation profile
Siller-Matula, J. M., Plasenzotti, R., Spiel, A., Quehenberger, P., & Jilma, B. (2008) · Thrombosis and Haemostasis · doi:10.1160/th08-02-0103 · Cited by 217
“One possible explanation for this might be the different sensitivity of each species to the recombinant human tissue factor, which was the activator in the endogenous thrombin generation assay (7).”
BackgroundMethodThrombin generation testing in routine clinical practice: are we there yet?
Van Veen, J. J., Gatt, A., & Makris, M. (2008) · British Journal of Haematology · doi:10.1111/j.1365-2141.2008.07267.x · Cited by 209
“…pill (COCP) or hormone replacement treatment (HRT) (Chantarangkul et al, 2003; Dargaud et al, 2006c; Eilertsen et al, 2007; van Hylckama Vlieg et al, 2007; Tchaikovski et al, 2007), 5 in patients with lupus anticoagulant (LA) (Regnault et al, 2003b, 2004; Lecompte et al, 2007; Liestol…”
BackgroundResultInfluentialTRIPODI, A., LEGNANI, C., CHANTARANGKUL, V., COSMI, B., PALARETI, G., & MANNUCCI, P. M. (2008) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2008.03018.x · Cited by 196
Metadata
- Authors
- Van Hylckama Vlieg, A., Christiansen, S. C., Luddington, R., Cannegieter, S. C., Rosendaal, F. R., & Baglin, T. P.
- Venue
- British Journal of Haematology
- Publisher
- Wiley
- Published
- 2007-08-23
- Volume
- 138
- Issue
- 6
- Pages
- 769-774
- ISSN
- 0007-1048 (ISSN-L)
- 1365-2141
- OpenAlex
- W1970393874
- Cited by
- 171
- References
- 4
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.