Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 318

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Thrombin Generation Assay and Its Application in the Clinical Laboratory

Tripodi, Armando·2016·Clinical Chemistry

Abstract

BACKGROUND: A gap exists between in vivo and ex vivo coagulation when investigated by use of the coagulation tests prothrombin time (PT) and activated partial thromboplastin time (APTT). The thrombin generation assay (TGA) has been developed to fill this gap. CONTENT: TGA evaluates thrombin generation (resulting from the action of the procoagulant driver) and decay (resulting from the action of the anticoagulant driver), thus assessing the balance between the two. Coagulation of the test plasma (platelet poor or platelet rich) is activated by small amounts of tissue factor and phospholipids, and the reaction of thrombin generation is continuously monitored by means of a thrombin-specific fluorogenic substrate. Among the parameters derived from the thrombin-generation curve, the most important is the endogenous thrombin potential, defined as the net amount of thrombin that test plasmas can generate on the basis of the relative strength of the pro- and anticoagulant drivers. TGA is therefore the candidate assay to investigate hypo- or hypercoagulability. SUMMARY: From my analysis of the literature, I draw the following conclusions. There is strong evidence that TGA is helpful to elucidate coagulation mechanisms in various clinical conditions that until recently were poorly understood (chronic liver disease; diabetes; inflammatory bowel disease, myeloproliferative neoplasms, nonalcoholic fatty liver disease). TGA is a promising laboratory tool for investigating hemorrhagic coagulopathies and monitoring replacement therapy in hemophiliacs, predicting the risk of recurrent venous thromboembolism after a first event, and monitoring patients on parenteral or oral anticoagulants. These applications require clinical trials in which TGA results are combined with specific clinical end points.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2015.248625

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 318

Metadata

Authors
Tripodi, A.
Venue
Clinical Chemistry
Published
2016-05-01
Volume
62
Issue
5
Pages
699-707
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2293439019
Cited by
318
References
34
FWCI
21.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thrombin Generation Assay and Its Application in the Clinical Laboratory. https://app.cochat.ai/papers/10.1373/clinchem.2015.248625
The paper
Tripodi, A. (2016). Thrombin Generation Assay and Its Application in the Clinical Laboratory. Clinical Chemistry. https://doi.org/10.1373/clinchem.2015.248625

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.