Pericellular oxygen monitoring with integrated sensor chips for reproducible cell culture experiments
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objectives: Here we present an application, in two tumour cell lines, based on the Sensing Cell Culture Flask system as a cell culture monitoring tool for pericellular oxygen sensing. Materials and methods: T‐47D (human breast cancer) and T98G (human brain cancer) cells were cultured either in atmospheric air or in a glove‐box set at 4% oxygen, in both cases with 5% CO 2 in the gas phase. Pericellular oxygen tension was measured with the help of an integrated sensor chip comprising oxygen sensor arrays. Results: Obtained results illustrate variation of pericellular oxygen tension in attached cells covered by stagnant medium. Independent of incubation conditions, low pericellular oxygen concentration levels, usually associated with hypoxia, were found in dense cell cultures. Conclusions: Respiration alone brought pericellular oxygen concentration down to levels which could activate hypoxia‐sensing regulatory processes in cultures believed to be aerobic. Cells in culture believed to experience conditions of mild hypoxia may, in reality, experience severe hypoxia. This would lead to incorrect assumptions and suggests that pericellular oxygen concentration readings are of great importance to obtain reproducible results when dealing with hypoxic and normoxic (aerobic) incubation conditions. The Sensing Cell Culture Flask system allows continuous monitoring of pericellular oxygen concentration with outstanding long‐term stability and no need for recalibration during cell culture experiments. The sensor is integrated into the flask bottom, thus in direct contact with attached cells. No additional equipment needs to be inserted into the flask during culturing. Transparency of the electrochemical sensor chip allows optical inspection of cells attached on top of the sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ACTION OF X-RAYS ON MAMMALIAN CELLS
Puck, T. T., & Marcus, P. I. (1956) · The Journal of Experimental Medicine · doi:10.1084/jem.103.5.653 · Cited by 1,696
Thin-Film Microbiosensors for Glucose−Lactate Monitoring
Jobst, G., Moser, I., Varahram, M., Svasek, P., Aschauer, E., Trajanoski, Z., Wach, P., Kotanko, P., Skrabal, F., & Urban, G. (1996) · Analytical Chemistry · doi:10.1021/ac950630x · Cited by 102
Self-citation
Cited by
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Liebisch, F., Weltin, A., Marzioch, J., Urban, G. A., & Kieninger, J. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128652 · Cited by 53
Self-citationCost-Effective Real-Time Metabolic Profiling of Cancer Cell Lines for Plate-Based Assays
Blaszczak, W., Tan, Z., & Swietach, P. (2021) · Chemosensors · doi:10.3390/chemosensors9060139 · Cited by 10
Metadata
- Authors
- Kieninger, J., Aravindalochanan, K., Sandvik, J. A., Pettersen, E. O., & Urban, G. A.
- Venue
- Cell Proliferation
- Publisher
- Wiley
- Published
- 2014-01-25
- Volume
- 47
- Issue
- 2
- Pages
- 180-188
- ISSN
- 0960-7722 (ISSN-L)
- 1365-2184
- OpenAlex
- W1983942588
- Cited by
- 40
- References
- 2
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pericellular oxygen monitoring with integrated sensor chips for reproducible cell culture experiments. https://app.cochat.ai/papers/10.1111/j.1365-2184.2013.12089.x
- The paper
- Kieninger, J., Aravindalochanan, K., Sandvik, J. A., Pettersen, E. O., & Urban, G. A. (2014). Pericellular oxygen monitoring with integrated sensor chips for reproducible cell culture experiments. Cell Proliferation. https://doi.org/10.1111/j.1365-2184.2013.12089.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.