CoChat

Clinical accuracy of a non‐contact infrared skin thermometer in paediatric practice

Teran, C. G., Torrez‐Llanos, J., Teran‐Miranda, T. E., Balderrama, C., Shah, N. S., Villarroel, P. · 2012 · Child: Care, Health and Development
Cited by 91

The DOI matches its Crossref record.

Abstract

Background Rectal thermometry is considered the most reliable method for measuring the temperature in the paediatric population. Recently, a new non‐contact skin infrared thermometer for children was introduced in the market with excellent acceptance by parents. Methods A prospective, analytical, cross‐sectional study was designed in order to assess the effectiveness of the infrared non‐contact thermometer (Thermofocus) in comparison with two other known methods used to measure body temperature. Children aged 1 to 48 months were included from the emergency room and inpatient unit. All patients selected were assessed with three different thermometers: (1) non‐contact infrared thermometer (Thermofocus); (2) temporal artery thermometer (Exergen); and (3) rectal glass mercury thermometer. Results Four hundred and thirty‐four patients were eligible to complete the study. One hundred and sixty‐seven were identified with fever. The mean age of the patients studied was 14.6 ± 10.7 months. Both devices were strongly correlated with the rectal temperature: r= 0.950 for Exergen and r= 0.952 for Thermofocus. The mean difference in temperature between the rectal temperature and the non‐contact thermometer was 0.029 ± 0.01°C (P < 0.001), while the mean difference between the temporal artery thermometer and the rectal temperature was −0.20 ± 0.27°C (P < 0.001). The sensitivity and specificity for the non‐contact thermometer is 97%. The negative predictive value is 99%, which is especially important to rule out fever and avoid unnecessary laboratory work‐up. Conclusions The non‐contact infrared thermometer is a reliable, comfortable and accurate option for measurement of temperature and is very useful for the screening of fever in the paediatric population. More studies are recommended to support the evidence found in this study and compare its accuracy with more complex devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2214.2011.01264.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 12

  1. 10.1080/15563650701664731 · DOI
  2. 10.1136/adc.2006.114314 · DOI
  3. Dinarello C. A., 1990, Principles and Practice of Infectious Diseases, 462
  4. 10.1136/adc.53.10.824 · doi:10.1136/adc.53.10.824
  5. 10.1097/01.PCC.0000163671.69197.16 · DOI · Paper page
  6. 10.1111/j.1744-6155.2009.00204.x · DOI
  7. 10.1136/adc.67.1.122 · DOI
  8. Osio C. E., 2007, Comparative study of body temperature measured with a non‐contact infrared thermometer versus conventional devices. The first Italian study on 90 pediatric patients, Minerva Pediatrica, 59, 327
  9. 10.1136/adc.2010.185801 · DOI · Paper page
  10. 10.1097/00008480-200102000-00016 · doi:10.1097/00008480-200102000-00016
  11. 10.1097/01.pec.0000144915.78124.26 · DOI · Paper page
  12. Sermet G. I., 2005, Body temperature measurement in daily practice, Archives of Pediatrics, 12, 292

Cited by

See all 91

Metadata

Authors
Teran, C. G., Torrez‐Llanos, J., Teran‐Miranda, T. E., Balderrama, C., Shah, N. S., & Villarroel, P.
Venue
Child: Care, Health and Development
Publisher
Wiley
Published
2011-06-08
Volume
38
Issue
4
Pages
471-476
ISSN
  • 0305-1862 (ISSN-L)
  • 1365-2214
OpenAlex
W1752987035
Cited by
91
References
0
FWCI
2.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical accuracy of a non‐contact infrared skin thermometer in paediatric practice. https://app.cochat.ai/papers/10.1111/j.1365-2214.2011.01264.x
The paper
Teran, C. G., Torrez‐Llanos, J., Teran‐Miranda, T. E., Balderrama, C., Shah, N. S., & Villarroel, P. (2012). Clinical accuracy of a non‐contact infrared skin thermometer in paediatric practice. Child: Care, Health and Development. https://doi.org/10.1111/j.1365-2214.2011.01264.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.