CoChat

Comparison of temporal artery thermometer to standard temperature measurements in pediatric intensive care unit patients

Hebbar, Kiran, Fortenberry, James D., Rogers, Kristine, Merritt, Robert, Easley, Kirk · 2005 · Pediatric Critical Care Medicine
Cited by 83

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To determine the accuracy of noninvasive infrared temporal artery thermometry compared with rectal, axillary, and pulmonary artery catheter measurements in pediatric intensive care patients, and to determine whether temporal artery temperatures are affected by circulatory shock or by vasopressor use. We hypothesized that temporal artery temperatures do not differ from axillary and rectal temperatures in critically ill children, but temporal artery accuracy is decreased by shock or vasopressor use. DESIGN: Observational study, unblinded. SETTING: Pediatric intensive care unit of a quarternary referral children's hospital. PATIENTS: Seventy-five temperature comparison pairs were obtained in 44 pediatric intensive care unit patients. INTERVENTIONS: Temperature measurements were made using a temporal artery thermometer with simultaneously obtained rectal, axillary, and, when available, pulmonary artery catheter measurements. MEASUREMENTS AND MAIN RESULTS: Mean bias was calculated between comparison pairs using each temperature method. Bland-Altman analysis demonstrated wide variability between methods. No significant differences in mean bias were seen between method pairs for all temperatures, but bias was significantly less in pulmonary artery catheter-rectal pairs compared with other method pairs. In febrile (> 38 degrees C) patients, bias in rectal-temporal artery and rectal-axillary was significantly greater than in temporal artery-axillary pairs (p < .001). Mean bias in pulmonary artery catheter-rectal pairs was also significantly smaller than in other pairs for all patients (p = .008) and febrile patients (p = .049). Presence of shock or vasopressor use did not significantly increase bias in any comparison pair. Sensitivity and specificity of both temporal artery and axillary for diagnosing fever were similar and improved with fever definition at temperatures > 38.5 degrees C. CONCLUSIONS: Temporal artery and axillary temperature measurements showed variability to rectal temperatures but had marked variability in febrile children. Neither was sufficiently accurate to recommend replacing rectal or other invasive methods. As temporal artery and axillary provide similar accuracy, temporal artery thermometers may serve as a suitable alternative for patients in whom invasive thermometry is contraindicated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.pcc.0000163671.69197.16

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 24

  1. Nierman, 1991, Crit Care Med, 19, 818, 10.1097/00003246-199106000-00015 · DOI · Paper page
  2. Robinson, 1998, J Pediatr, 133, 553, 10.1016/S0022-3476(98)70067-8 · DOI
  3. Giuliano, 1999, Crit Care Med, 27, 2307, 10.1097/00003246-199910000-00020 · DOI · Paper page
  4. Fallis, 2002, Am J Crit Care, 11, 38, 10.4037/ajcc2002.11.1.38 · DOI
  5. Lefrant, 2003, Intensive Care Med, 29, 414, 10.1007/s00134-002-1619-5 · DOI · Paper page
  6. Muma, 1991, Ann Emerg Med, 20, 41, 10.1016/S0196-0644(05)81116-3 · DOI
  7. Frank, 1978, Arch Dis Child, 53, 824, 10.1136/adc.53.10.824 · doi:10.1136/adc.53.10.824
  8. Im, 1981, J Hosp Infect, 2, 171, 10.1016/0195-6701(81)90026-8 · doi:10.1016/0195-6701(81)90026-8
  9. Buck, 1989, Pediatrics, 83, 782, 10.1542/peds.83.5.782 · DOI
  10. Schimpff, 1972, Lancet, 2, 844, 10.1016/S0140-6736(72)92210-6 · doi:10.1016/s0140-6736(72)92210-6
  11. Kenney, 1990, Pediatrics, 85, 854, 10.1542/peds.85.5.854 · DOI
  12. Freed, 1992, Pediatrics, 89, 384, 10.1542/peds.89.3.384 · doi:10.1542/peds.89.3.384
  13. Romano, 1993, Crit Care Med, 21, 1181, 10.1097/00003246-199308000-00018 · DOI
  14. Craig, 2002, Lancet, 360, 603, 10.1016/S0140-6736(02)09783-0 · DOI · Paper page
  15. Zengeya, 1996, Eur J Pediatr, 155, 1005, 10.1007/BF02532519 · DOI
  16. Weisse, 1991, Pediatr Infect Dis J, 10, 541, 10.1097/00006454-199107000-00013 · doi:10.1097/00006454-199107000-00013
  17. Androkoites, 1998, J Pediatr Oncol Nurs, 15, 216, 10.1177/104345429801500404 · doi:10.1177/104345429801500404
  18. Siberry, 2002, Clin Pediatr, 41, 405, 10.1177/000992280204100605 · DOI
  19. Greenes, 2001, Arch Pediatr Adolesc Med, 155, 376, 10.1001/archpedi.155.3.376 · DOI · Paper page
  20. Roy, 2003, Clin Pediatr, 42, 433, 10.1177/000992280304200508 · doi:10.1177/000992280304200508
  21. Harioka, 2000, Can J Anaesth, 47, 980, 10.1007/BF03024869 · DOI
  22. Obuchowski, 1998, Stat Med, 17, 1495, 10.1002/(SICI)1097-0258(19980715)17:13<1495::AID-SIM863>3.0.CO;2-I · DOI
  23. Greenes, 2004, J Pediatr, 144, 824
  24. Maxton, 2004, J Adv Nurs, 45, 214, 10.1046/j.1365-2648.2003.02883.x · DOI · Paper page

Cited by

See all 83

Metadata

Authors
Hebbar, K., Fortenberry, J. D., Rogers, K., Merritt, R., & Easley, K.
Venue
Pediatric Critical Care Medicine
Published
2005-09
Volume
6
Issue
5
Pages
557-561
ISSN
1529-7535 (ISSN-L)
OpenAlex
W2032660588
Cited by
83
References
1
FWCI
2.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of temporal artery thermometer to standard temperature measurements in pediatric intensive care unit patients. https://app.cochat.ai/papers/10.1097/01.pcc.0000163671.69197.16
The paper
Hebbar, K., Fortenberry, J. D., Rogers, K., Merritt, R., & Easley, K. (2005). Comparison of temporal artery thermometer to standard temperature measurements in pediatric intensive care unit patients. Pediatric Critical Care Medicine. https://doi.org/10.1097/01.pcc.0000163671.69197.16

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.