The diagnostic interpretation of basophil activation test in immediate allergic reactions to betalactams

Open access
Torres, M. J., Padial, A., Mayorga, C., Fernández, T., Sanchez‐Sabate, E., Cornejo‐García, J. A., Antúnez, C., Blanca, M.·2004·Clinical & Experimental Allergy

Abstract

Summary: Background Basophil activation by allergens, including drugs, has been used to determine sensitivity and to study IgE recognition and cross‐reactivity. Objective We sought to determine the sensitivity and specificity of a basophil activation test (Basotest) in patients with immediate allergic reactions to betalactams, with a later comparison between patients who were selective (those recognizing the culprit drug excluding benzylpenicillin (BP)) and cross‐reactors (those recognizing several penicillin determinants including BP). Methods Basotest to different haptens was performed in 70 patients with immediate allergic reactions to betalactams, classified into three groups: (A) skin test positive independently of CAP/RAST immunoassay value, (B) skin test negative and CAP/RAST positive, and (C) skin test and CAP/RAST negative but drug provocation test positive. Basotest was carried out by flow cytometry following the manufacturer's instructions using different betalactam determinants and results expressed as a stimulation index. Results Of the 70 patients, 34 (48.6%) were positive to Basotest (sensitivity: 48.6%), 31 (44.3%) to CAP/RAST and 46 (65.7%) to either one or the other. Considering the different groups, Basotest was positive in 50.9% of patients in Group A, 60% in Group B and 14.3% in Group C. The specificity was 91.3%. Positivity to the haptens was 28.6% to amoxicillin (AX), 21.7% to BP, 20% to benzylpenicilloyl‐poly‐l‐lysine, 12.5% to ampicillin and 2.2% to minor determinant mixture. In patients with cephalosporin reactions, Basotest to the culprit cephalosporin was positive in 77.7%. There were differences between the two reactor groups in the sensitivity of Basotest (selective to AX=50%, cross‐reactors=28.6%; χ 2=10.809, P=0.004) and in the CAP/RAST (selective to AX=28.6%, cross‐reactors=61.9%; χ 2=8.944, P=0.011). Conclusions The sensitivity of Basotest is similar to immunoassays (CAP/RAST). Sensitivity is improved when used in combination. Although further studies are required, Basotest results for cephalosporin allergy seem very promising. This technique does not help differentiate between selective reactors and cross‐reactors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2222.2004.02110.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 184

Metadata

Authors
Torres, M. J., Padial, A., Mayorga, C., Fernández, T., Sanchez‐Sabate, E., Cornejo‐García, J. A., Antúnez, C., & Blanca, M.
Venue
Clinical & Experimental Allergy
Publisher
Wiley
Published
2004-11
Volume
34
Issue
11
Pages
1768-1775
ISSN
  • 0954-7894 (ISSN-L)
  • 1365-2222
OpenAlex
W2094887277
Cited by
184
References
2
FWCI
2.35
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The diagnostic interpretation of basophil activation test in immediate allergic reactions to betalactams. https://app.cochat.ai/papers/10.1111/j.1365-2222.2004.02110.x
The paper
Torres, M. J., Padial, A., Mayorga, C., Fernández, T., Sanchez‐Sabate, E., Cornejo‐García, J. A., Antúnez, C., & Blanca, M. (2004). The diagnostic interpretation of basophil activation test in immediate allergic reactions to betalactams. Clinical & Experimental Allergy. https://doi.org/10.1111/j.1365-2222.2004.02110.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.