Raised tryptase without anaphylaxis or mastocytosis: heterophilic antibody interference in the serum tryptase assay
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: Mast cell tryptase (MCT) is a key diagnostic test for mastocytosis and anaphylaxis. High serum tryptase levels are also one of the risk factors for adverse reaction in venom immunotherapy, yet occasional patients are seen with raised levels in the absence of either diagnosis. False positive results can be due to assay interference by heterophilic antibodies such as rheumatoid factor (RF) and human anti-mouse antibodies (HAMA). We therefore investigated heterophilic antibody interference by rheumatoid factor activity and HAMA as a cause of raised MCT results in the Phadia tryptase assay. Serum samples from 83 patients were assayed for MCT and rheumatoid factor before and after the use of heterophilic antibody blocking tubes (HBT). Samples with more than 17% reduction in MCT with detectable RF were then assayed for HAMA. Fourteen (17%) of the 83 samples with positive RF showed a >17% decrease in mast cell tryptase after HBT blocking. Post-HBT, eight of 14 (57%) reverted from elevated to normal range values with falls of up to 98%. RF levels were also decreased significantly (up to 75%). Only one of the 83 tested was apparently affected by HAMA in the absence of detectable IgM RF. In conclusion, any suspicious MCT result should be checked for heterophilic antibodies to evaluate possible interference. False positive MCT levels can be caused by rheumatoid factor. We suggest a strategy for identifying assay interference, and show that it is essential to incorporate this caveat into guidance for interpretation of MCT results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of a new, more sensitive immunoassay for human tryptase: use in systemic anaphylaxis
Schwartz, L. B., Bradford, T. R., Rouse, C., Irani, A.-M., Rasp, G., Van Der Zwan, J. K., & Van Der Linden, P.-W. G. (1994) · Journal of Clinical Immunology · doi:10.1007/bf01533368 · Cited by 263
Cited by
Human mast cell tryptase in biology and medicine
Vitte, J. (2015) · Molecular Immunology · doi:10.1016/j.molimm.2014.04.001 · Cited by 152
The serum tryptase test: an emerging robust biomarker in clinical hematology
Valent, P., Sperr, W. R., Sotlar, K., Reiter, A., Akin, C., Gotlib, J., Horny, H.-P., & Arock, M. (2014) · Expert Review of Hematology · doi:10.1586/17474086.2014.955008 · Cited by 83
Elevated Basal Serum Tryptase: Disease Distribution and Variability in a Regional Health System
Waters, A. M., Park, H. J., Weskamp, A. L., Mateja, A., Kachur, M. E., Lyons, J. J., Rosen, B. J., & Boggs, N. A. (2022) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2021.12.031 · Cited by 46
Immunology and clinical manifestations of non-clonal mast cell activation syndrome
Cardet, J.-C., Castells, M. C., & Hamilton, M. J. (2013) · Current Allergy and Asthma Reports · doi:10.1007/s11882-012-0326-8 · Cited by 39
“There is some evidence to suggest that rheumatoid factor (RF) interferes with the tryptase assay to yield falsely elevated levels and that the use of heterophile antibody blocking tubes normalizes the levels in more than half of RF + samples with elevated total tryptase [52].”
Elevated Serum Tryptase in Non-Anaphylaxis Cases: A Concise Review
Lee, A. Y. S. (2020) · International Archives of Allergy and Immunology · doi:10.1159/000506199 · Cited by 36
Egner, W., Sargur, R., Shrimpton, A., York, M., & Green, K. (2016) · Clinical & Experimental Allergy · doi:10.1111/cea.12785 · Cited by 31
Self-citationVysniauskaite, M., Hertfelder, H.-J., Oldenburg, J., Dreßen, P., Brettner, S., Homann, J., & Molderings, G. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124912 · Cited by 30
“Tryptase level in blood > 20 ng/ml SM: ~ 80–85% ([16]; further references therein); 77% [39] in the absence of hematologic malignancies and end-stage kidney disease specific for mast cells; 10% falsely elevated results due to interference with rheumatoid factor [45] MCAS: 8% [40]; 22% [41]; 0% [42, 43]; 21% [39]; 33%…”
BackgroundPersistent tryptase elevation in a patient with Gaucher disease
Schussler, E., Yang, A., Lyons, J. J., Milner, J. D., & Wang, J. (2018) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2017.08.039 · Cited by 13
“Heterophile antibody interference can lead to false positive tryptase assay results.(8) Evaluation of common heterophile antibodies Schussler et al.”
BackgroundSerum concentrations of mast cell tryptase are reduced in heavy drinkers
Beceiro, C., Campos, J., Valcarcel, M.-A., Fenger, R. V., Lojo, S., Linneberg, A., Vidal, C., & Gonzalez-Quintela, A. (2015) · Alcoholism Clinical and Experimental Research · doi:10.1111/acer.12682 · Cited by 9
“Falsely increased tryptase concentrations have been reported in samples containing heterophile antibodies (Sargur et al., 2011), but this interference is considered to be minor in common practice (Schliemann et al.”
Background
Metadata
- Authors
- Sargur, R., Cowley, D., Murng, S., Wild, G., Green, K., Shrimpton, A., & Egner, W.
- Venue
- Clinical and Experimental Immunology
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-02-08
- Volume
- 163
- Issue
- 3
- Pages
- 339-345
- ISSN
- 0009-9104 (ISSN-L)
- 1365-2249
- OpenAlex
- W1569846655
- Cited by
- 27
- References
- 1
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.