CLINICAL EVALUATION OF A TWO‐SITE IMMUNORADIOMETRIC ASSAY FOR ADRENOCORTICOTROPIC IN UNEXTRACTED HUMAN PLASMA USING MONOCLONAL ANTIBODIES
The DOI matches its Crossref record.
Abstract
SUMMARY: We have developed a sensitive two‐site immunoradiometric assay (IRMA) for intact ACTH and its precursors, pro‐opiomelanocortin and 22 kDa peptide in unextracted human plasma. The assay uses two monoclonal antibodies. Antibody 1A12, specific for ACTH 10–18, is radiolabelled and antibody 2A3 specific for the C‐terminal region (ACTH 24–39), is coupled to Sephacryl S300 for the solid‐phase. Samples are incubated for 18 h with labelled antibody followed by 2 h with solid‐phase antibody. Separation employs the sucrose layering technique. Using human pituitary ACTH 1–39 (code 74/555) in diluent containing 10% horse serum to standardize the assay, the sensitivity (upper 99% confidence limit of zero standard) is 3.5 ± 0.8 ng/l (n= 7). The mean coefficient of variation is 5.9% within‐assay and 6.7% between‐assay and is less than 10% between 22 and >5000 ng/l. Mean recovery of ACTH 1–39 added to dexamethasone‐suppressed human plasma is 109% and endogenous ACTH behaves indistinguishably from standard ACTH on dilution. In normal subjects, mean plasma ACTH levels are 30 ng/l at 0730 h, and 15 ng/1 at 1630 h at rest. ACTH concentrations are between 60 and 330 ng/l, 8–10.5 h after metyrapone (2 g orally at 2300 h), between 140 and 320 ng/1, 30–60 min after insulin‐induced hypoglycaemia, and < 4 ng/1, 8 h after dexamethasone (1.5 mg orally at 2300 h). In a range of pathological conditions ACTH concentrations accurately reflect the disorders of the pituitary‐adrenal axis. Endogenous ACTH immunoactivity is stable in vitro at 22°C for at least 1 h in whole blood and at least 4 h in plasma. It is concluded that this two‐site IRMA for ACTH in unextracted plasma offers a reliable assay for clinical purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
POMC: The Physiological Power of Hormone Processing
Harno, E., Gali Ramamoorthy, T., Coll, A. P., & White, A. (2018) · Physiological Reviews · doi:10.1152/physrev.00024.2017 · Cited by 262
Self-citationO'Rahilly, S., Gray, H., Humphreys, P. J., Krook, A., Polonsky, K. S., White, A., Gibson, S., Taylor, K., & Carr, C. (1995) · New England Journal of Medicine · doi:10.1056/nejm199511233332104 · Cited by 237
Self-citationFarooqi, I. S., Volders, K., Stanhope, R., Heuschkel, R., White, A., Lank, E., Keogh, J., O’Rahilly, S., & Creemers, J. W. M. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-0687 · Cited by 218
Self-citationAssessment of ACTH assay variability: a multicenter study
Pecori Giraldi, F., Saccani, A., Cavagnini, F., & _, _. (2011) · European Journal of Endocrinology · doi:10.1530/eje-10-0962 · Cited by 80
LITTLEY, M. D., GIBSON, S., WHITES, A., & SHALET, M. (1989) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1989.tb01276.x · Cited by 68
Metadata
- Authors
- WHITE, A., SMITH, H., HOADLEY, M., DOBSON, S. H., & RATCLIFFE, J. G.
- Venue
- Clinical Endocrinology
- Publisher
- Wiley
- Published
- 1987-01
- Volume
- 26
- Issue
- 1
- Pages
- 41-52
- ISSN
- 0300-0664 (ISSN-L)
- 1365-2265
- OpenAlex
- W2114420323
- Cited by
- 108
- References
- 0
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CLINICAL EVALUATION OF A TWO‐SITE IMMUNORADIOMETRIC ASSAY FOR ADRENOCORTICOTROPIC IN UNEXTRACTED HUMAN PLASMA USING MONOCLONAL ANTIBODIES. https://app.cochat.ai/papers/10.1111/j.1365-2265.1987.tb03637.x
- The paper
- WHITE, A., SMITH, H., HOADLEY, M., DOBSON, S. H., & RATCLIFFE, J. G. (1987). CLINICAL EVALUATION OF A TWO‐SITE IMMUNORADIOMETRIC ASSAY FOR ADRENOCORTICOTROPIC IN UNEXTRACTED HUMAN PLASMA USING MONOCLONAL ANTIBODIES. Clinical Endocrinology. https://doi.org/10.1111/j.1365-2265.1987.tb03637.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.