An Investigation of Errors in Direct Counts of Aquatic Bacteria by Epifluorescence Microscopy, with Reference to a New Method for Dyeing Membrane Filters
The DOI matches its Crossref record.
Abstract
A number of methods for observing freshwater bacteria by epifluorescence (incident light fluorescence) microscopy are examined. The suitability of each method for quantitative studies using black membrane filters is assessed. In spite of inadequacies it was considered that the use of acridine‐based fluorochromes provided the best available estimate of the bacterial population. The errors which may arise when these stains are used were examined and it was noted that small changes in methodology could cause significant differences in the results obtained. The largest errors were associated with changes in volume of sample filtered and the pore size of the membrane used. A procedure for sample treatment is suggested and a new method for dyeing membrane filters is given which allows the use of 0·22‐μm pore size membranes of the cellulose ester and polycarbonate type.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Use of nuclepore filters for counting bacteria by fluorescence microscopy
Hobbie, J. E., Daley, R. J., & Jasper, S. (1977) · Applied and Environmental Microbiology · doi:10.1128/aem.33.5.1225-1228.1977 · Cited by 4,244
Survival strategies of bacteria in the natural environment
Roszak, D. B., & Colwell, R. R. (1987) · Microbiological Reviews · doi:10.1128/mmbr.51.3.365-379.1987 · Cited by 1,758
Kepner, R. L., & Pratt, J. R. (1994) · Microbiological Reviews · doi:10.1128/mmbr.58.4.603-615.1994 · Cited by 797
Zimmermann, R., Iturriaga, R., & Becker-Birck, J. (1978) · Applied and Environmental Microbiology · doi:10.1128/aem.36.6.926-935.1978 · Cited by 568
2 Direct Methods and Biomass Estimation
Fry, J. C. (1990) · Methods in Microbiology · doi:10.1016/s0580-9517(08)70239-3 · Cited by 314
Collection of airborne micro‐organisms on Nuclepore filters, estimation and analysis—CAMNEA method
Palmgren, U., Ström, G., Blomquist, G., & Malmberg, P. (1986) · Journal of Applied Bacteriology · doi:10.1111/j.1365-2672.1986.tb04303.x · Cited by 259
van Veen, J. A., & Paul, E. A. (1979) · Applied and Environmental Microbiology · doi:10.1128/aem.37.4.686-692.1979 · Cited by 246
Terzieva, S., Donnelly, J., Ulevicius, V, Grinshpun, S. A., Willeke, K., Stelma, G. N., & Brenner, K. P. (1996) · Applied and Environmental Microbiology · doi:10.1128/aem.62.7.2264-2272.1996 · Cited by 220
The assessment of bioaerosols: A critical review
Griffiths, W. D., & DeCosemo, G. A. L. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90218-6 · Cited by 215
Statistical analysis of the direct count method for enumerating bacteria
Kirchman, D., Sigda, J., Kapuscinski, R., & Mitchell, R. (1982) · Applied and Environmental Microbiology · doi:10.1128/aem.44.2.376-382.1982 · Cited by 211
“Some microbiologists count ten fields, whereas others examine fields until a given number of cells, typically 200 to 400, have been counted (11).”
BackgroundFluorescein Diacetate as a Stain of Metabolically Active Bacteria in Soil
Lundgren, B., & Lundgren, B. (1981) · Oikos · doi:10.2307/3544373 · Cited by 163
“8 (Ebony Black, Dylon International Ltd, London, England) to reduce the autofluorescence of the filter (Jones and Simon 1975).”
BackgroundBaumstummler, A., Chollet, R., Meder, H., Rofel, C., Venchiarutti, A., & Ribault, S. (2010) · Letters in Applied Microbiology · doi:10.1111/j.1472-765x.2010.02952.x · Cited by 13
“The detection of low contamination level can be solved by increasing the volume of sample filtered (Jones and Simon 1975).”
Background
Metadata
- Authors
- JONES, J. G., & SIMON, B. M.
- Venue
- Journal of Applied Bacteriology
- Publisher
- Wiley
- Published
- 1975-12
- Volume
- 39
- Issue
- 3
- Pages
- 317-329
- ISSN
- 0021-8847 (ISSN-L)
- OpenAlex
- W1970677340
- Cited by
- 151
- References
- 0
- FWCI
- 18.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.