Flow cytometry for rapid assessment of viability after exposure to a quaternary ammonium compound
The DOI matches its Crossref record.
Abstract
The use of flow cytometry to rapidly assess the viability of Pseudomonas spp. and Staphylococcus spp. after exposure to a quaternary ammonium compound (QAC) was investigated using rhodamine 123 (Rh 123), Stain A (LIVE Stain) accumulating in viable but not in dead cells (Live/Dead Bac light bacterial viability kit, Molecular Probes Inc., Eugene, OR, USA), and Sytox green (Molecular Probes) accumulating in dead but not viable cells. Staining conditions were optimized for each stain. The fraction of viable cells after exposure to benzalkonium chloride was determined by using the three staining techniques and colony counts on agar medium. For all Staphylococcus spp. tested there was a high correlation between the methods based on flow cytometry and colony counts irrespective of which stain was used. Although viable, all Pseudomonas spp. tested accumulated Rh 123 poorly and about 30% failed to accumulate LIVE stain as well. However, the correlation between colony counts and Sytox green labelling of Pseudomonas spp. was high. Our results indicate that flow cytometry together with live or dead cell labelling can be used to study the bactericidal effect of QACs. The methods based on LIVE stain and Sytox green were simpler and less time consuming than Rh 123 labelling. Only Sytox green could be used with all strains of Staphylococcvs and Pseudomonas tested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stiefel, P., Schmidt-Emrich, S., Maniura-Weber, K., & Ren, Q. (2015) · BMC Microbiology · doi:10.1186/s12866-015-0376-x · Cited by 710
Bacterial viability and antibiotic susceptibility testing with SYTOX green nucleic acid stain
Roth, B. L., Poot, M., Yue, S. T., & Millard, P. J. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.6.2421-2431.1997 · Cited by 579
Mechanism and use of the commercially available viability stain, Bac Light
Stocks, S. M. (2004) · Cytometry Part A · doi:10.1002/cyto.a.20069 · Cited by 369
Use of fluorescent probes to assess physiological functions of bacteriaat single-cell level
Joux, F., & Lebaron, P. (2000) · Microbes and Infection · doi:10.1016/s1286-4579(00)01307-1 · Cited by 365
Applications of flow cytometry to clinical microbiology
Álvarez-Barrientos, A., Arroyo, J., Cantón, R., Nombela, C., & Sánchez-Pérez, M. (2000) · Clinical Microbiology Reviews · doi:10.1128/cmr.13.2.167 · Cited by 300
“) have been used for the FCM-based counting of live and dead bacteria and yeasts (176, 178, 311), simplifying staining protocols and making data interpretation easier.”
Method
Metadata
- Authors
- Langsrud, S., & Sundheim, G.
- Venue
- Journal of Applied Bacteriology
- Publisher
- Wiley
- Published
- 1996-10
- Volume
- 81
- Issue
- 4
- Pages
- 411-418
- ISSN
- 0021-8847 (ISSN-L)
- OpenAlex
- W2077010704
- Cited by
- 77
- References
- 0
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flow cytometry for rapid assessment of viability after exposure to a quaternary ammonium compound. https://app.cochat.ai/papers/10.1111/j.1365-2672.1996.tb03527.x
- The paper
- Langsrud, S., & Sundheim, G. (1996). Flow cytometry for rapid assessment of viability after exposure to a quaternary ammonium compound. Journal of Applied Bacteriology. https://doi.org/10.1111/j.1365-2672.1996.tb03527.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.