The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Antibody-aptamer functionalized fibre-optic biosensor for specific detection of Listeria monocytogenes from food: Antibody-aptamer fibre-optic sensor for L. monocytogenes
Abstract
AIM: To develop antibody-aptamer functionalized fibre-optic biosensor for specific detection of Listeria monocytogenes from food products. METHODS AND RESULTS: Aptamer, a single-stranded oligonucleotide ligand that displays affinity for the target molecule, was used in the assay to provide sensor specificity. Aptamer-A8, specific for internalin A, an invasive protein of L. monocytogenes, was used in the fibre-optic sensor together with antibody in a sandwich format for detection of L. monocytogenes from food. Biotinylated polyclonal anti-Listeria antibody, P66, was immobilized on streptavidin-coated optical waveguide surface for capturing bacteria, and Alexa Fluor 647-conjugated A8 was used as a reporter. The biosensor was able to selectively detect pathogenic Listeria in pure culture and in mixture with other bacteria at a concentration of approx. 10(3) CFU ml(-1). This sensor also successfully detected L. monocytogenes cells from artificially contaminated (initial inoculation of 10(2) CFU 25 g(-1) ) ready-to-eat meat products such as sliced beef, chicken and turkey after 18 h of enrichment. CONCLUSION: Based on the data presented in this study, the antibody-aptamer functionalized fibre-optic biosensor could be used as a detection tool for sensitive and specific detection of L. monocytogenes from foods. SIGNIFICANCE AND IMPACT OF THE STUDY: The study demonstrates feasibility and novel application of aptamer on fibre-optic biosensor platform for the sensitive detection of L. monocytogenes from food products.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schubert, W.-D., Urbanke, C., Ziehm, T., Beier, V., Machner, M. P., Domann, E., Wehland, J., Chakraborty, T., & Heinz, D. W. (2002) · Cell · doi:10.1016/s0092-8674(02)01136-4 · Cited by 302
Cited by
Biosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Aptamer Based SPREETA Sensor for the Detection of Porphyromonas gingivalis G-Protein
Park, S.-G., Lee, H. J., Ji, T., Kim, K., & Ohk, S.-H. (2024) · Journal of Microbiology and Biotechnology · doi:10.4014/jmb.2310.10042 · Cited by 2
Self-citation
Metadata
- Authors
- Ohk, S. H., Koo, O. K., Sen, T., Yamamoto, C. M., & Bhunia, A. K.
- Venue
- Journal of Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-08-16
- Volume
- 109
- Issue
- 3
- Pages
- 808-817
- ISSN
- 1364-5072 (ISSN-L)
- OpenAlex
- W1674147318
- Cited by
- 182
- References
- 1
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antibody-aptamer functionalized fibre-optic biosensor for specific detection of Listeria monocytogenes from food: Antibody-aptamer fibre-optic sensor for L. monocytogenes. https://app.cochat.ai/papers/10.1111/j.1365-2672.2010.04709.x
- The paper
- Ohk, S. H., Koo, O. K., Sen, T., Yamamoto, C. M., & Bhunia, A. K. (2010). Antibody-aptamer functionalized fibre-optic biosensor for specific detection of Listeria monocytogenes from food: Antibody-aptamer fibre-optic sensor for L. monocytogenes. Journal of Applied Microbiology. https://doi.org/10.1111/j.1365-2672.2010.04709.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.