Abstract
This review presents evidence that ambulatory blood pressure measurement (ABPM) should be used more widely in clinical practice and hypertension research. The technique, which should be mandatory in trials of antihypertensive drugs, is not being used in all studies of antihypertensive drug efficacy. ABPM is also being under-used in outcome studies. The failure to implement ABPM in primary care and hypertension research is impeding patient management and scientific advancement. ABPM offers so many advantages in assessing the efficacy of blood pressure (BP)-lowering drugs that it should be mandatory in pharmacological trials. Likewise, the technique provides a means of achieving BP control in clinical practice, which is essential if we are to halt the epidemic of the cardiovascular consequences of hypertension. However, if ABPM is to be implemented for these purposes, certain requirements will need to be fulfilled. These include the availability of accurate, patient-friendly and inexpensive devices; standardization of the presentation and plotting of data with summary statistics for day-to-day practice; provision of comprehensive data analysis for research; an interpretative report to facilitate use in busy clinical practice; a trend report to demonstrate efficacy or otherwise of treatment in clinical practice and online transmission of data to provide immediate real-time data analysis. The reasons why ABPM is not being implemented are reviewed, and proposals are made to make the technique more acceptable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A., Fagard, R., Thijs, L., Celis, H., Arabidze, G. G., Birkenhäger, W. H., Bulpitt, C. J., de Leeuw, P. W., Dollery, C. T., Fletcher, A. E., et al. (1997) · The Lancet · doi:10.1016/s0140-6736(97)05381-6 · Cited by 2,989
Self-citationRothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Sever, P. S., & Poulter, N. R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60308-x · Cited by 1,784
Self-citationO'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Kario, K., Pickering, T. G., Umeda, Y., Hoshide, S., Hoshide, Y., Morinari, M., Murata, M., Kuroda, T., Schwartz, J. E., & Shimada, K. (2003) · Circulation · doi:10.1161/01.cir.0000056521.67546.aa · Cited by 1,250
Dolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227
Self-citationSega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationMancia, G., Facchetti, R., Bombelli, M., Grassi, G., & Sega, R. (2006) · Hypertension · doi:10.1161/01.hyp.0000215363.69793.bb · Cited by 691
Rothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Poulter, N. R., & Sever, P. S. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70066-1 · Cited by 690
Self-citationKikuya, M., Ohkubo, T., Asayama, K., Metoki, H., Obara, T., Saito, S., Hashimoto, J., Totsune, K., Hoshi, H., Satoh, H., et al. (2005) · Hypertension · doi:10.1161/01.hyp.0000152079.04553.2c · Cited by 417
Prevalence and Factors Associated With Circadian Blood Pressure Patterns in Hypertensive Patients
de la Sierra, A., Redon, J., Banegas, J. R., Segura, J., Parati, G., Gorostidi, M., de la Cruz, J. J., Sobrino, J., Llisterri, J. L., Alonso, J., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.124008 · Cited by 379
Mancia, G., & Parati, G. (2004) · Journal of Hypertension · doi:10.1097/00004872-200403000-00001 · Cited by 219
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationStergiou, G. S., Palatini, P., Asmar, R., Bilo, G., de la Sierra, A., Head, G., Kario, K., Mihailidou, A., Wang, J., Mancia, G., et al. (2018) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000301 · Cited by 57
Self-citationPatterns of ambulatory blood pressure: clinical relevance and application
O'Brien, E., Kario, K., Staessen, J. A., de la Sierra, A., & Ohkubo, T. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13277 · Cited by 40
Self-citation
Metadata
- Authors
- O’Brien, E.
- Venue
- Journal of Internal Medicine
- Publisher
- Wiley
- Published
- 2011-03-14
- Volume
- 269
- Issue
- 5
- Pages
- 478-495
- ISSN
- 0954-6820 (ISSN-L)
- OpenAlex
- W1571636077
- Cited by
- 71
- References
- 14
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.