A computer system for the measurement of cell and nuclear sizes*
The DOI matches its Crossref record.
Abstract
SUMMARY: A semi‐automated system has been developed for the measurement of cell (perikaryal), nuclear and nucleolar areas. The system consists essentially of a Graf/Pen data tablet (with its associated acoustical stylus and tablet electronics), an optical input system such as a camera lucida, and a small digital computer. The perikaryal, nuclear and nucleolar outlines are traced in sequence with the stylus which, on contacting the tablet surface, emits a high frequency acoustic wave that is sensed by X and Y strip microphones along the left and upper edges of the tablet. The acoustic signal is converted by a simple program into a series of X and Y coordinates which are sampled at several points around the perimeter of the profile. When the stylus tip re‐enters a 1 mm stationary window set up around the starting point, the measurement is automatically terminated and the data for this profile is printed out and stored in memory for subsequent statistical analysis. The system has an overall accuracy of about 1% and in practice it has been possible to measure objects at least ten times more rapidly than by any of the other currently available methods. The hardware and software features of the system are detailed and a number of additional uses for the system are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sawchenko, P. E., & Swanson, L. W. (1982) · Journal of Comparative Neurology · doi:10.1002/cne.902050306 · Cited by 1,150
The connections of the septal region in the rat
Swanson, L. W., & Cowan, W. M. (1979) · Journal of Comparative Neurology · doi:10.1002/cne.901860408 · Cited by 1,135
Self-citationSchlessinger, A. R., Cowan, W. M., & Gottlieb, D. I. (1975) · Journal of Comparative Neurology · doi:10.1002/cne.901590202 · Cited by 731
Self-citationWise, S. P., & Jones, E. G. (1977) · Journal of Comparative Neurology · doi:10.1002/cne.901750202 · Cited by 524
Size, laminar and columnar distribution of efferent cells in the sensory‐motor cortex of monkeys
Jones, E. G., & Wise, S. P. (1977) · Journal of Comparative Neurology · doi:10.1002/cne.901750403 · Cited by 508
Metadata
- Authors
- Cowan, W. M., & Wann, F.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1973-12
- Volume
- 99
- Issue
- 3
- Pages
- 331-348
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2138014752
- Cited by
- 86
- References
- 0
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A computer system for the measurement of cell and nuclear sizes*. https://app.cochat.ai/papers/10.1111/j.1365-2818.1973.tb04630.x
- The paper
- Cowan, W. M., & Wann, F. (1973). A computer system for the measurement of cell and nuclear sizes*. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1973.tb04630.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.