Total internal reflection fluorescent microscopy
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
SUMMARY: This review discusses applications of fluorescence microscopy using totally internally reflected excitation light. When totally internally reflected in a transparent solid at its interface with liquid, the excitation light beam penetrates only a short distance into the liquid. This surface electromagnetic field, called the ‘evanescent wave’, can selectively excite fluorescent molecules in the liquid near the interface. Total internal reflection fluorescence (TIRF) has been used to examine the cell/substrate contact regions of primary cultured rat myotubes with acetylcholine receptors labelled by fluorescent α‐bungarotoxin and human skin fibroblasts labelled with a membrane‐incorporated fluorescent lipid. TIRF examination of cell/substrate contacts dramatically reduces background from cell autofluorescence and debris. TIRF has also been combined with fluorescence photobleaching recovery and correlation spectroscopy to measure the chemical kinetic binding rates and surface diffusion constant of fluorescent labelled serum protein binding (at equilibrium) to a surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mobility measurement by analysis of fluorescence photobleaching recovery kinetics
Axelrod, D., Koppel, D. E., Schlessinger, J., Elson, E., & Webb, W. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85755-4 · Cited by 2,714
Self-citationInternal Reflection Spectroscopy
Wilks, P. A., & Hirschfeld, T. (1967) · Applied Spectroscopy Reviews · doi:10.1080/05704926708547582 · Cited by 1,478
Fluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Cell-substrate contacts illuminated by total internal reflection fluorescence.
Axelrod, D. (1981) · The Journal of cell biology · doi:10.1083/jcb.89.1.141 · Cited by 832
Self-citationIzzard, C. S., & Lochner, L. R. (1976) · Journal of Cell Science · doi:10.1242/jcs.21.1.129 · Cited by 705
Carbocyanine dye orientation in red cell membrane studied by microscopic fluorescence polarization
Axelrod, D. (1979) · Biophysical Journal · doi:10.1016/s0006-3495(79)85271-6 · Cited by 528
Self-citationAxelrod, D., Ravdin, P., Koppel, D. E., Schlessinger, J., Webb, W. W., Elson, E. L., & Podleski, T. R. (1976) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.73.12.4594 · Cited by 387
Self-citationThompson, N. L., Burghardt, T. P., & Axelrod, D. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84905-3 · Cited by 316
Self-citationQuantitative reflection contrast microscopy of living cells.
Bereiter-Hahn, J., Fox, C. H., & Thorell, B. (1979) · The Journal of cell biology · doi:10.1083/jcb.82.3.767 · Cited by 195
Weis, R. M., Balakrishnan, K., Smith, B. A., & McConnell, H. M. (1982) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(20)65161-4 · Cited by 119
Cited by
Fort, E., & Grésillon, S. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/1/013001 · Cited by 697
Accuracy and precision in quantitative fluorescence microscopy
Waters, J. C. (2009) · Journal of Cell Biology · doi:10.1083/jcb.200903097 · Cited by 613
“In total internal reflection (TIRF) microscopy, fluorophores are excited with the evanescent wave of energy that forms when total internal reflection occurs at the boundary between media of different refractive indexes, usually the coverslip and the specimen (Axelrod et al., 1983).”
BackgroundAnnular pupils, radial polarization, and superresolution
Sheppard, C. J. R., & Choudhury, A. (2004) · Applied Optics · doi:10.1364/ao.43.004322 · Cited by 345
Crouzier, T., Ren, K., Nicolas, C., Roy, C., & Picart, C. (2009) · Small · doi:10.1002/smll.200800804 · Cited by 251
Morphology and dynamics of perisynaptic glia
Reichenbach, A., Derouiche, A., & Kirchhoff, F. (2010) · Brain Research Reviews · doi:10.1016/j.brainresrev.2010.02.003 · Cited by 251
Kyriazis, G. A., Soundarapandian, M. M., & Tyrberg, B. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1115183109 · Cited by 232
Dubin-Thaler, B. J., Giannone, G., Döbereiner, H.-G., & Sheetz, M. P. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74246-0 · Cited by 219
“This is achieved by exploiting the high contrast between contact and noncontact regions in images obtained using total internal reflection fluorescence (TIRF) microscopy (Axelrod et al., 1983).”
BackgroundLabouèbe, G., Lomazzi, M., Cruz, H. G., Creton, C., Luján, R., Li, M., Yanagawa, Y., Obata, K., Watanabe, M., Wickman, K., et al. (2007) · Nature Neuroscience · doi:10.1038/nn2006 · Cited by 208
Moving into the cell: single-molecule studies of molecular motors in complex environments
Veigel, C., & Schmidt, C. F. (2011) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3062 · Cited by 176
Integrin Signaling Switches the Cytoskeletal and Exocytic Machinery that Drives Neuritogenesis
Gupton, S. L., & Gertler, F. B. (2010) · Developmental Cell · doi:10.1016/j.devcel.2010.02.017 · Cited by 172
“To characterize vesicle dynamics, we performed live cell total internal reflection fluorescence microscopy (TIR-FM, (Axelrod et al., 1983) of GFP-tagged v-SNAREs expressed at low levels (Fig 5A-D), which localize with endogenous proteins (Fig S3).”
Chapter 7 Total Internal Reflection Fluorescence Microscopy
Axelrod, D. (2008) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)00607-9 · Cited by 172
Self-citationPhysics and applications of terahertz metagratings
Rane, S., Department of Physics, É. C. S. O. E., Prabhu, S., Chowdhury, D. R., & Department of Condensed Matter Physics and Material Science, T. I. O. F. R. (2024) · Opto-Electronic Science · doi:10.29026/oes.2024.230049 · Cited by 169
Zhang, X.-F., Schaefer, A. W., Burnette, D. T., Schoonderwoert, V. T., & Forscher, P. (2003) · Neuron · doi:10.1016/s0896-6273(03)00754-2 · Cited by 169
Metadata
- Authors
- Axelrod, D., Thompson, N. L., & Burghardt, T. P.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 129
- Issue
- 1
- Pages
- 19-28
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2078800834
- Cited by
- 214
- References
- 11
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.