The DOI matches its Crossref record.
Restoration of confocal images for quantitative image analysis
Abstract
SUMMARY: Quantitative studies of three‐dimensional (3‐D) structure of microscopic objects have been made possible through the introduction of microscopic volume imaging techniques, most notably the confocal fluorescence microscope (CFM). Although the CFM is a true volume imager, its specific imaging properties give rise to distortions in the images and hamper subsequent quantitative analysis. Therefore, it is a prerequisite that confocal images are restored prior to analysis. The distortions can be divided into several categories: attenuation of areas in the image due to self‐absorption, bleaching effects, geometrical effects and distortions due to diffraction effects. Of these, absorption and diffraction effects are the most important. This paper describes a method aimed at the correction of diffraction‐induced distortions. All the steps necessary in restoring confocal images are discussed, including a novel method to measure instrumental properties on a routine basis. To test the restoration procedure an image of a fluorescent planar object was restored. The results show a considerable improvement in the z‐resolution and no ringing artefacts. The relevance of the method for image analysis is demonstrated by a comparison of results of applying 3‐D texture analysis to restored and unrestored images of a synthetic object. Furthermore, the method can be successfully applied to noisy fluorescence images of biological objects, such as interphase cell nucei.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deconvolution methods for 3-D fluorescence microscopy images
Sarder, P., & Nehorai, A. (2006) · IEEE Signal Processing Magazine · doi:10.1109/msp.2006.1628876 · Cited by 479
van Steensel, B., van Binnendijk, E. P., Hornsby, C. D., van der Voort, H. T. M., Krozowski, Z. S., de Kloet, E. R., & van Driel, R. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.4.787 · Cited by 357
Self-citationSoeller, C., & Cannell, M. B. (1999) · Circulation Research · doi:10.1161/01.res.84.3.266 · Cited by 331
Two-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Quantitative 3D Tracing of Gene-delivery Viral Vectors in Human Cells and Animal Tissues
Xiao, P.-J., Li, C., Neumann, A., & Samulski, R. J. (2012) · Molecular Therapy · doi:10.1038/mt.2011.250 · Cited by 33
Metadata
- Authors
- VAN DER VOORT, H. T. M., & STRASTERS, K. C.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1995-05
- Volume
- 178
- Issue
- 2
- Pages
- 165-181
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2165769351
- Cited by
- 186
- References
- 0
- FWCI
- 60.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Restoration of confocal images for quantitative image analysis. https://app.cochat.ai/papers/10.1111/j.1365-2818.1995.tb03593.x
- The paper
- VAN DER VOORT, H. T. M., & STRASTERS, K. C. (1995). Restoration of confocal images for quantitative image analysis. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1995.tb03593.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.