Restoration of confocal images for quantitative image analysis
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
SUMMARY: Quantitative studies of three‐dimensional (3‐D) structure of microscopic objects have been made possible through the introduction of microscopic volume imaging techniques, most notably the confocal fluorescence microscope (CFM). Although the CFM is a true volume imager, its specific imaging properties give rise to distortions in the images and hamper subsequent quantitative analysis. Therefore, it is a prerequisite that confocal images are restored prior to analysis. The distortions can be divided into several categories: attenuation of areas in the image due to self‐absorption, bleaching effects, geometrical effects and distortions due to diffraction effects. Of these, absorption and diffraction effects are the most important. This paper describes a method aimed at the correction of diffraction‐induced distortions. All the steps necessary in restoring confocal images are discussed, including a novel method to measure instrumental properties on a routine basis. To test the restoration procedure an image of a fluorescent planar object was restored. The results show a considerable improvement in the z‐resolution and no ringing artefacts. The relevance of the method for image analysis is demonstrated by a comparison of results of applying 3‐D texture analysis to restored and unrestored images of a synthetic object. Furthermore, the method can be successfully applied to noisy fluorescence images of biological objects, such as interphase cell nucei.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
Richards, B., & Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0200 · Cited by 3,095
On the rationale of maximum-entropy methods
Jaynes, E. T. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12425 · Cited by 1,297 · cited 1×
“Others, known from other application fields, such as the maximum entropy (Jaynes, 1982), may also be applicable.”
BackgroundCsiszar, I. (1991) · The Annals of Statistics · doi:10.1214/aos/1176348385 · Cited by 790
Electromagnetic diffraction in optical systems - I. An integral representation of the image field
Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0199 · Cited by 789
Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index
HELL, S., REINER, G., CREMER, C., & STELZER, E. H. K. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03315.x · Cited by 640
Bracewell, R. N. (1983) · Journal of the Optical Society of America · doi:10.1364/josa.73.001832 · Cited by 445
Iterative Identification and Restoration of Images
Lagendijk, R. L., & Biemond, J. (1991) · Springer eBooks · doi:10.1007/978-1-4615-3980-3 · Cited by 345
Deblurring subject to nonnegativity constraints
Snyder, D. L., Schulz, T. J., & O'Sullivan, J. A. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.134477 · Cited by 224 · cited 1×
“, 1990), maximum likelihood estimation (MLE; Lagendijk, 1990; Conchello & Hansen, 1990; Holmes & Liu, 1991; Csiszir, 1991; Snyder et al., 1992) and blind deconvolution (Holmes, 1992).”
Blind deconvolution of quantum-limited incoherent imagery: maximum-likelihood approach
Holmes, T. J. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.001052 · Cited by 205
Cited by
Deconvolution methods for 3-D fluorescence microscopy images
Sarder, P., & Nehorai, A. (2006) · IEEE Signal Processing Magazine · doi:10.1109/msp.2006.1628876 · Cited by 479
van Steensel, B., van Binnendijk, E. P., Hornsby, C. D., van der Voort, H. T. M., Krozowski, Z. S., de Kloet, E. R., & van Driel, R. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.4.787 · Cited by 357
Self-citationSoeller, C., & Cannell, M. B. (1999) · Circulation Research · doi:10.1161/01.res.84.3.266 · Cited by 331
Two-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Cmarko, D., Verschure, P. J., Martin, T. E., Dahmus, M. E., Krause, S., Fu, X.-D., van Driel, R., & Fakan, S. (1999) · Molecular Biology of the Cell · doi:10.1091/mbc.10.1.211 · Cited by 252
“Images were subjected to a restoration procedure to correct for diffraction-induced distortion using a measured point-spread function (van der Voort and Straster, 1995).”
MethodSpatial Relationship between Transcription Sites and Chromosome Territories
Verschure, P. J., van der Kraan, I., Manders, E. M. M., & van Driel, R. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.147.1.13 · Cited by 250
“D image restoration procedure to correct for diffraction-induced distortion, using the Huygens System 2 (Scientific Volume Imaging BV; Van der Voort and Straster, 1985).”
Dynamics of the nuclear lamina as monitored by GFP-tagged A-type lamins
Broers, J. L. V., Machiels, B. M., van Eys, G. J. J. M., Kuijpers, H. J. H., Manders, E. M. M., van Driel, R., & Ramaekers, F. C. S. (1999) · Journal of Cell Science · doi:10.1242/jcs.112.20.3463 · Cited by 246
Grande, M. A., Kraan, I. V. D., Jong, L. D., & Driel, R. V. (1997) · Journal of Cell Science · doi:10.1242/jcs.110.15.1781 · Cited by 223
Rust, R. C., Landmann, L., Gosert, R., Tang, B. L., Hong, W., Hauri, H.-P., Egger, D., & Bienz, K. (2001) · Journal of Virology · doi:10.1128/jvi.75.20.9808-9818.2001 · Cited by 213
“Switzerland) operating in the maximum-likelihood estimation mode (84) and”
BackgroundBuchenau, P., Hodgson, J., Strutt, H., & Arndt-Jovin, D. J. (1998) · The Journal of Cell Biology · doi:10.1083/jcb.141.2.469 · Cited by 200
“Image restoration was performed by deconvolution of the fluorescence data using the Huygens module of the Imaris software that uses a maximum likelihood estimation algorithm (van der Voort and Straster, 1995).”
MethodDigital Image Reconstruction: Deblurring and Denoising
Puetter, R. C., Gosnell, T. R., & Yahil, A. (2005) · Annual Review of Astronomy and Astrophysics · doi:10.1146/annurev.astro.43.112904.104850 · Cited by 160
Quantitative 3D Tracing of Gene-delivery Viral Vectors in Human Cells and Animal Tissues
Xiao, P.-J., Li, C., Neumann, A., & Samulski, R. J. (2012) · Molecular Therapy · doi:10.1038/mt.2011.250 · Cited by 33
Metadata
- Authors
- VAN DER VOORT, H. T. M., & STRASTERS, K. C.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1995-05
- Volume
- 178
- Issue
- 2
- Pages
- 165-181
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2165769351
- Cited by
- 186
- References
- 14
- FWCI
- 60.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.