Vitrification of articular cartilage by high‐pressure freezing
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Summary: For more than 20 years, high‐pressure freezing has been used to cryofix bulk biological specimens and reports are available in which the potential and limits of this method have been evaluated mostly based on morphological criteria. By evaluating the presence or absence of segregation patterns, it was postulated that biological samples of up to 600 μm in thickness could be vitrified by high‐pressure freezing. The cooling rates necessary to achieve this result under high‐pressure conditions were estimated to be of the order of several hundred degrees kelvin per second. Recent results suggest that the thickness of biological samples which can be vitrified may be much less than previously believed. It was the aim of this study to explore the potential and limits of high‐pressure freezing using theoretical and experimental methods. A new high‐pressure freezing apparatus (Leiċa EM HPF), which can generate higher cooling rates at the sample surface than previously possible, was used. Using bovine articular cartilage as a model tissue system, we were able to vitrify 150‐μm‐thick tissue samples. Vitrification was proven by subjecting frozen‐hydrated cryosections to electron diffraction analysis and was found to be dependent on the proteoglycan concentration and water content of the cartilage. Only the lower radical zone (with a high proteoglycan concentration and a low water content compared to the other zones) could be fully vitrified. Our theoretical calculations indicated that applied surface cooling rates in excess of 5000 K/s can be propagated into specimen centres only if samples are relatively thin (<200 μm). These calculations, taken together with our zone‐dependent attainment of vitrification in 150‐μm‐thick cartilage samples, suggest that the critical cooling rates necessary to achieve vitrification of biological samples under high‐pressure freezing conditions are significantly higher (1000–100 000 K/s) than previously proposed, but are reduced by about a factor of 100 when compared to cooling rates necessary to vitrify biological samples at ambient pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE USE OF LEAD CITRATE AT HIGH pH AS AN ELECTRON-OPAQUE STAIN IN ELECTRON MICROSCOPY
Reynolds, E. S. (1963) · The Journal of Cell Biology · doi:10.1083/jcb.17.1.208 · Cited by 24,938
Tranter, C. J. (1959) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(59)90029-8 · Cited by 18,388
Cryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389
Heuser, J. E., Reese, T. S., Dennis, M. J., Jan, Y., Jan, L., & Evans, L. (1979) · The Journal of cell biology · doi:10.1083/jcb.81.2.275 · Cited by 1,415
Structure and biology of cartilage and bone matrix noncollagenous macromolecules
Heinegård, D., & Oldberg, Å. (1989) · The FASEB Journal · doi:10.1096/fasebj.3.9.2663581 · Cited by 565
Mechanism of longitudinal bone growth and its regulation by growth plate chondrocytes
Hunziker, E. B. (1994) · Microscopy Research and Technique · doi:10.1002/jemt.1070280606 · Cited by 461
Self-citationTheory and Practice of High Pressure Freezing
Moor, H. (1987) · Cryotechniques in Biological Electron Microscopy · doi:10.1007/978-3-642-72815-0_8 · Cited by 448
Electron microscopy after rapid freezing on a metal surface and substitution fixation
van Harreveld, A., & Crowell, J. (1964) · The Anatomical Record · doi:10.1002/ar.1091490307 · Cited by 365
High pressure freezing comes of age.
Studer, D., Michel, M., & Müller, M. (1989) · PubMed · Cited by 360
Self-citationCalcium content of mitochondria and endoplasmic reticulum in liver frozen rapidly in vivo
Somlyo, A. P., Bond, M., & Somlyo, A. V. (1985) · Nature · doi:10.1038/314622a0 · Cited by 356
Electron microscopy of frozen-hydrated bacteria
Dubochet, J., McDowall, A. W., Menge, B., Schmid, E. N., & Lickfeld, K. G. (1983) · Journal of Bacteriology · doi:10.1128/jb.155.1.381-390.1983 · Cited by 278
Chandrasekhar, S., Esterman, M. A., & Hoffman, H. A. (1987) · Analytical Biochemistry · doi:10.1016/0003-2697(87)90658-0 · Cited by 260
High‐pressure freezing of cell suspensions in cellulose capillary tubes
HOHENBERG, H., MANNWEILER, K., & MÜLLER, M. (1994) · Journal of Microscopy · doi:10.1111/j.1365-2818.1994.tb04785.x · Cited by 234
The influence of high pressure freezing on mammalian nerve tissue
Moor, H., Bellin, G., Sandri, C., & Akert, K. (1980) · Cell and Tissue Research · doi:10.1007/bf00237626 · Cited by 167
Vitrification depth can be increased more than 10‐fold by high‐pressure freezing
Blanc, N. S., Richter, K., & Dubochet, J. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03393.x · Cited by 139
Changes in freeze-fractured mitochondrial membranes correlated to their energetic state
Knoll, G., & Brdiczka, D. G. (1983) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(83)90095-0 · Cited by 133
High-pressure freezing of soybean nodules leads to an improved preservation of ultrastructure
Studer, D., Hennecke, H., & M�ller, M. (1992) · Planta · doi:10.1007/bf00216809 · Cited by 88
Self-citationRapid freezing of deep cerebral structures for electron microscopy
Harreveld, A. V., & Fifkova´, E. (1975) · The Anatomical Record · doi:10.1002/ar.1091820311 · Cited by 33
Effect of high‐pressure freezing on plant microfilament bundles
Ding, B., Turgeon, R., & Parthasarathy, M. V. (1992) · Journal of Microscopy · doi:10.1111/j.1365-2818.1992.tb01493.x · Cited by 31
Cited by
Nephrin strands contribute to a porous slit diaphragm scaffold as revealed by electron tomography
Wartiovaara, J., Öfverstedt, L.-G., Khoshnoodi, J., Zhang, J., Mäkelä, E., Sandin, S., Ruotsalainen, V., Cheng, R. H., Jalanko, H., Skoglund, U., et al. (2004) · Journal of Clinical Investigation · doi:10.1172/jci22562 · Cited by 319
Walther, P., & Ziegler, A. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01064.x · Cited by 292
Studer, D., Humbel, B. M., & Chiquet, M. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0500-1 · Cited by 286
Self-citationA new approach for cryofixation by high‐pressure freezing
Studer, D., Graber, W., Al‐Amoudi, A., & Eggli, P. (2001) · Journal of Microscopy · doi:10.1046/j.1365-2818.2001.00919.x · Cited by 286
Self-citationZuber, B., Nikonenko, I., Klauser, P., Muller, D., & Dubochet, J. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509527102 · Cited by 260
Metadata
- Authors
- STUDER, D., MICHEL, M., WOHLWEND, M., HUNZIKER, E. B., & BUSCHMANN, M. D.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1995-09
- Volume
- 179
- Issue
- 3
- Pages
- 321-322
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2169489226
- Cited by
- 186
- References
- 19
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.