The DOI matches its Crossref record.
High‐resolution compact X‐ray microscopy
Abstract
Summary: We demonstrate compact full‐field soft X‐ray transmission microscopy with sub 60‐nm resolution operating at λ= 2.48 nm. The microscope is based on a 100‐Hz regenerative liquid‐nitrogen‐jet laser‐plasma source in combination with a condenser zone plate and a micro‐zone plate objective for high‐resolution imaging onto a 2048 × 2048 pixel CCD detector. The sample holder is mounted in a helium atmosphere and allows imaging of both dry and wet specimens. The microscope design enables fast sample switching and the sample can be pre‐aligned using a visible‐light microscope. High‐quality images can be acquired with exposure times of less than 5 min. We demonstrate the performance of the microscope using both dry and wet samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sakdinawat, A., & Attwood, D. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.267 · Cited by 728
Probing Liquid/Solid Interfaces at the Molecular Level
Zaera, F. (2012) · Chemical Reviews · doi:10.1021/cr2002068 · Cited by 458
Liu, Y., Meirer, F., Williams, P. A., Wang, J., Andrews, J. C., & Pianetta, P. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511049144 · Cited by 278
Physics and technology development of multilayer EUV reflective optics
Louis, E. (2022) · doi:10.3990/1.9789090271637 · Cited by 6
Metadata
- Authors
- TAKMAN, P. A. C., STOLLBERG, H., JOHANSSON, G. A., HOLMBERG, A., LINDBLOM, M., & HERTZ, H. M.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2007-04-17
- Volume
- 226
- Issue
- 2
- Pages
- 175-181
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2018683262
- Cited by
- 160
- References
- 0
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐resolution compact X‐ray microscopy. https://app.cochat.ai/papers/10.1111/j.1365-2818.2007.01765.x
- The paper
- TAKMAN, P. A. C., STOLLBERG, H., JOHANSSON, G. A., HOLMBERG, A., LINDBLOM, M., & HERTZ, H. M. (2007). High‐resolution compact X‐ray microscopy. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.2007.01765.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.