High‐resolution compact X‐ray microscopy
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Summary: We demonstrate compact full‐field soft X‐ray transmission microscopy with sub 60‐nm resolution operating at λ= 2.48 nm. The microscope is based on a 100‐Hz regenerative liquid‐nitrogen‐jet laser‐plasma source in combination with a condenser zone plate and a micro‐zone plate objective for high‐resolution imaging onto a 2048 × 2048 pixel CCD detector. The sample holder is mounted in a helium atmosphere and allows imaging of both dry and wet specimens. The microscope design enables fast sample switching and the sample can be pre‐aligned using a visible‐light microscope. High‐quality images can be acquired with exposure times of less than 5 min. We demonstrate the performance of the microscope using both dry and wet samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soft X-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D. (1999) · Cambridge University Press eBooks · doi:10.1017/cbo9781139164429 · Cited by 1,014 · cited 1×
“The theoretical resolution in an X-ray microscope is limited by the outermost zone width of the zone plate (Attwood, 1999).”
BackgroundSoft X-ray microscopy at a spatial resolution better than 15 nm
Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H., & Attwood, D. T. (2005) · Nature · doi:10.1038/nature03719 · Cited by 851 · cited 2×
“Zone plates with zone widths down to 15 nm were recently demonstrated by Chao et al. (2005) .”
BackgroundSoft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672 · cited 2×
“37 nm) provides a unique set of high-resolution imaging capabilities that complement visible light and electron microscopy (Schmahl et al., 1980; Kirz et al., 1995).”
BackgroundInfluentialLarabell, C. A., & Le Gros, M. A. (2004) · Molecular Biology of the Cell · doi:10.1091/mbc.e03-07-0522 · Cited by 282 · cited 1×
“radiation damage. Such a module would also enable X-ray tomography for 3D imaging ( Larabell & Le Gros, 2004 ).”
BackgroundDiffraction-limited imaging in a scanning transmission x-ray microscope
Jacobsen, C., Williams, S., Anderson, E., Browne, M. T., Buckley, C. J., Kern, D., Kirz, J., Rivers, M., & Zhang, X. (1991) · Optics Communications · doi:10.1016/0030-4018(91)90016-7 · Cited by 244 · cited 2×
“X-ray microscopy can also be operated in scanning mode, something which was first demonstrated by Kirz et al. at Stony Brook (Rarback et al., 1980; Jacobsen et al., 1991).”
MethodHigh-reflectivity Cr∕Sc multilayer condenser for compact soft x-ray microscopy
Stollberg, H., Yulin, S. A., Takman, P. A. C., & Hertz, H. M. (2006) · Review of Scientific Instruments · doi:10.1063/1.2400665 · Cited by 35 · cited 4×
“Even though normalincidence multilayer condenser mirrors are available at λ = 3.37 nm ( Stollberg et al., 2006 ) no mirrors have shown the required reflectivity and the necessary uniformity on sufficiently large substrates for λ = 2.48 nm. The condenser zone plate has a diameter of 4.53 mm and an outermost zone width…”
BackgroundInfluentialSelf-citation
Cited by
Sakdinawat, A., & Attwood, D. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.267 · Cited by 728
Probing Liquid/Solid Interfaces at the Molecular Level
Zaera, F. (2012) · Chemical Reviews · doi:10.1021/cr2002068 · Cited by 458
Liu, Y., Meirer, F., Williams, P. A., Wang, J., Andrews, J. C., & Pianetta, P. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511049144 · Cited by 278
Soft X-ray tomography and cryogenic light microscopy: the cool combination in cellular imaging
McDermott, G., Le Gros, M. A., Knoechel, C. G., Uchida, M., & Larabell, C. A. (2009) · Trends in Cell Biology · doi:10.1016/j.tcb.2009.08.005 · Cited by 185
Transmission and emission x-ray microscopy: operation modes, contrast mechanisms and applications
Kaulich, B., Thibault, P., Gianoncelli, A., & Kiskinova, M. (2011) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/23/8/083002 · Cited by 169
“We describe a type of TXM instrument developed at the BIOX facility of the KTH Stockholm, Sweden (Takman et al 2007, Hertz et al 2009), which works in the water window dedicated exclusively to studies of biological samples.”
MethodPhysics and technology development of multilayer EUV reflective optics
Louis, E. (2022) · doi:10.3990/1.9789090271637 · Cited by 6
Metadata
- Authors
- TAKMAN, P. A. C., STOLLBERG, H., JOHANSSON, G. A., HOLMBERG, A., LINDBLOM, M., & HERTZ, H. M.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2007-04-17
- Volume
- 226
- Issue
- 2
- Pages
- 175-181
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2018683262
- Cited by
- 160
- References
- 6
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.