The DOI matches its Crossref record.
Moving EM: the Rapid Transfer System as a new tool for correlative light and electron microscopy and high throughput for high‐pressure freezing
Abstract
Summary: In this paper, the Rapid Transfer System (RTS), an attachment to the Leica EMPACT2 high‐pressure freezer, is described as a new tool for special applications within the cryofixation field. The RTS is an automated system that allows for fast processing of samples (<5 s) that make it possible for the first time to use high‐pressure freezing in combination with high time resolution correlative light and electron microscopy. In addition, with a working cycle of 30 s this rapid turn over time allows one to acquire more samples of biopsy material before it deteriorates than with other HPF machines with longer cycle times. With the use of the RTS it was possible to obtain three samples each of four different tissues in 6 min. Together with the finding that 90% of samples of cells grown on sapphire discs were well frozen, the RTS was both fast and reliable. Most important, together with other newly developed accessories, the RTS made it possible to capture specific events occurring live in the cell as observed by light microscopy, to cryofix that sample/event within 4 s, and then to analyze that event at high resolution in the electron microscope with excellent preservation of ultra‐structure. These developments should give us the tools to unravel intracellular processes that can be observed by live cell imaging but are too rare or fast to be picked up by routine EM methods or where the history of a structure is necessary to be able to discern its nature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Correlated fluorescence and 3D electron microscopy with high sensitivity and spatial precision
Kukulski, W., Schorb, M., Welsch, S., Picco, A., Kaksonen, M., & Briggs, J. A. G. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201009037 · Cited by 467
Studer, D., Humbel, B. M., & Chiquet, M. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0500-1 · Cited by 286
Self-Assembly of Nanofilaments in Cyanobacteria for Protein Co-localization
Zedler, J. A. Z., Schirmacher, A. M., Russo, D. A., Hodgson, L., Gundersen, E., Matthes, A., Frank, S., Verkade, P., & Jensen, P. E. (2023) · ACS Nano · doi:10.1021/acsnano.3c08600 · Cited by 17
Self-citation
Metadata
- Authors
- VERKADE, P.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2008-04-25
- Volume
- 230
- Issue
- 2
- Pages
- 317-328
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2019541950
- Cited by
- 165
- References
- 0
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Moving EM: the Rapid Transfer System as a new tool for correlative light and electron microscopy and high throughput for high‐pressure freezing. https://app.cochat.ai/papers/10.1111/j.1365-2818.2008.01989.x
- The paper
- VERKADE, P. (2008). Moving EM: the Rapid Transfer System as a new tool for correlative light and electron microscopy and high throughput for high‐pressure freezing. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.2008.01989.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.