Moving EM: the Rapid Transfer System as a new tool for correlative light and electron microscopy and high throughput for high‐pressure freezing
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Summary: In this paper, the Rapid Transfer System (RTS), an attachment to the Leica EMPACT2 high‐pressure freezer, is described as a new tool for special applications within the cryofixation field. The RTS is an automated system that allows for fast processing of samples (<5 s) that make it possible for the first time to use high‐pressure freezing in combination with high time resolution correlative light and electron microscopy. In addition, with a working cycle of 30 s this rapid turn over time allows one to acquire more samples of biopsy material before it deteriorates than with other HPF machines with longer cycle times. With the use of the RTS it was possible to obtain three samples each of four different tissues in 6 min. Together with the finding that 90% of samples of cells grown on sapphire discs were well frozen, the RTS was both fast and reliable. Most important, together with other newly developed accessories, the RTS made it possible to capture specific events occurring live in the cell as observed by light microscopy, to cryofix that sample/event within 4 s, and then to analyze that event at high resolution in the electron microscope with excellent preservation of ultra‐structure. These developments should give us the tools to unravel intracellular processes that can be observed by live cell imaging but are too rare or fast to be picked up by routine EM methods or where the history of a structure is necessary to be able to discern its nature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multicolor and Electron Microscopic Imaging of Connexin Trafficking
Gaietta, G., Deerinck, T. J., Adams, S. R., Bouwer, J., Tour, O., Laird, D. W., Sosinsky, G. E., Tsien, R. Y., & Ellisman, M. H. (2002) · Science · doi:10.1126/science.1068793 · Cited by 907 · cited 3×
“Examples of these are the ReAsh compound (Gaietta et al., 2002) and quantum dots (Giepmans et al., 2005).”
BackgroundAPPL Proteins Link Rab5 to Nuclear Signal Transduction via an Endosomal Compartment
Miaczynska, M., Christoforidis, S., Giner, A., Shevchenko, A., Uttenweiler-Joseph, S., Habermann, B., Wilm, M., Parton, R. G., & Zerial, M. (2004) · Cell · doi:10.1016/s0092-8674(04)00117-5 · Cited by 539 · cited 1×
“The internalization and trafficking of these EGF-markers happens in the same way as EGF coupled to a fluorescent marker alone (a marker that is generally used for studies involving EGF internalization (Miaczynska et al., 2004), data not shown).”
BackgroundCryo‐electron microscopy of vitreous sections
Al‐Amoudi, A., Chang, J., Leforestier, A., McDowall, A., Salamin, L. M., Norlén, L. P., Richter, K., Blanc, N. S., Studer, D., & Dubochet, J. (2004) · The EMBO Journal · doi:10.1038/sj.emboj.7600366 · Cited by 456
Theory and Practice of High Pressure Freezing
Moor, H. (1987) · Cryotechniques in Biological Electron Microscopy · doi:10.1007/978-3-642-72815-0_8 · Cited by 448 · cited 6×
“That loading the sample is a crucial step was already realized by C© 2008 The Author Journal compilation C© 2008 The Royal Microscopical Society, Journal of Microscopy, 230, 317–328 the ‘founding father’ of HPF Hans Moor (Moor, 1987).”
BackgroundInfluentialFelder, S., Miller, K., Moehren, G., Ullrich, A., Schlessinger, J., & Hopkins, C. R. (1990) · Cell · doi:10.1016/0092-8674(90)90474-s · Cited by 445 · cited 4×
“The MVB in the example is seen as a translucent structure, since the content is not visualized well (mainly fluid, little protein or lipid).”
BackgroundInfluentialCorrelated light and electron microscopic imaging of multiple endogenous proteins using Quantum dots
Giepmans, B. N. G., Deerinck, T. J., Smarr, B. L., Jones, Y. Z., & Ellisman, M. H. (2005) · Nature Methods · doi:10.1038/nmeth791 · Cited by 388 · cited 3×
“Examples of these are the ReAsh compound (Gaietta et al., 2002) and quantum dots (Giepmans et al., 2005).”
BackgroundHigh pressure freezing comes of age.
Studer, D., Michel, M., & Müller, M. (1989) · PubMed · Cited by 360
Walther, P., & Ziegler, A. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01064.x · Cited by 292 · cited 2×
“Thus, the effect would be the same as observed by Walther and Ziegler (2002).”
BackgroundA new approach for cryofixation by high‐pressure freezing
Studer, D., Graber, W., Al‐Amoudi, A., & Eggli, P. (2001) · Journal of Microscopy · doi:10.1046/j.1365-2818.2001.00919.x · Cited by 286 · cited 6×
“As the basic principle of the EM PACT2 is the same as for the EM PACT, the reader is referred to the paper of Studer (Studer et al., 2001) for further technical details.”
BackgroundMethodResultInfluentialRapid and effective labeling of brain tissue using TAT-conjugated CdS∶Mn/ZnS quantum dots
Santra, S., Yang, H., Stanley, J. T., Holloway, P. H., Moudgil, B. M., Walter, G., & Mericle, R. A. (2005) · Chemical Communications · doi:10.1039/b503234b · Cited by 215 · cited 1×
“People have succeeded in constructing quantum dots that are able to cross the plasma membrane (Santra et al., 2005).”
Background
Cited by
Correlated fluorescence and 3D electron microscopy with high sensitivity and spatial precision
Kukulski, W., Schorb, M., Welsch, S., Picco, A., Kaksonen, M., & Briggs, J. A. G. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201009037 · Cited by 467
Studer, D., Humbel, B. M., & Chiquet, M. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0500-1 · Cited by 286
Townley, A. K., Feng, Y., Schmidt, K., Carter, D. A., Porter, R., Verkade, P., & Stephens, D. J. (2008) · Journal of Cell Science · doi:10.1242/jcs.031070 · Cited by 174
“Jekyll is caused by a mutation in UDP-glucose dehydrogenase that results in defective proteoglycan secretion (Walsh and Stainier, 2001).”
BackgroundSelf-citationIntegrated fluorescence and transmission electron microscopy
Agronskaia, A. V., Valentijn, J. A., van Driel, L. F., Schneijdenberg, C. T. W. M., Humbel, B. M., van Bergen en Henegouwen, P. M. P., Verkleij, A. J., Koster, A. J., & Gerritsen, H. C. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.07.003 · Cited by 168
“This limitation has motivated researchers to embark on the development of imaging methods that combine FM and EM—correlative microscopy (Powell et al., 1997; Takizawa et al., 1998; Mironov et al., 2000; Polishchuk et al., 2000; Gaietta et al., 2002; Sartori et al., 2007; Verkade, 2008).”
MethodImaging three-dimensional tissue architectures by focused ion beam scanning electron microscopy
Bushby, A. J., P'ng, K. M. Y., Young, R. D., Pinali, C., Knupp, C., & Quantock, A. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.332 · Cited by 160
“Innovative methods for correlative microscopy combining these two modalities have also been develope”
MethodSelf-Assembly of Nanofilaments in Cyanobacteria for Protein Co-localization
Zedler, J. A. Z., Schirmacher, A. M., Russo, D. A., Hodgson, L., Gundersen, E., Matthes, A., Frank, S., Verkade, P., & Jensen, P. E. (2023) · ACS Nano · doi:10.1021/acsnano.3c08600 · Cited by 17
Self-citationSubstrate Inhibition of VanA by d-Alanine Reduces Vancomycin Resistance in a VanX-Dependent Manner
van der Aart, L. T., Lemmens, N., van Wamel, W. J., & van Wezel, G. P. (2016) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00276-16 · Cited by 15
Metadata
- Authors
- VERKADE, P.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2008-04-25
- Volume
- 230
- Issue
- 2
- Pages
- 317-328
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2019541950
- Cited by
- 165
- References
- 26
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.