Stress distribution in a post‐restored tooth using the three‐dimensional finite element method
The DOI matches its Crossref record.
Abstract
summary Clinicians are opting ever more frequently for restorative materials which have an elastic modulus similar to that of dentin when reconstructing endodontically treated teeth. Metallic posts, which are capable of causing dangerous and non‐homogenous stresses in root dentin, are slowly being abandoned. Ideal posts may be those made of various types of fibre (carbon, mineral and glass) and which are adhesively luted into the canal. Among the different methods for evaluating the mechanical behaviour of posts in root canals (progressive loads and photo‐elastic technique) the finite element method (FEM) presents many advantages. The aim of this paper is to evaluate, utilizing three‐dimensional analysis of the finite elements, what the effect of material rigidity, depth of insertion and post diameter could be on the stress distribution in the different components of the single tooth‐post‐core reconstruction unit. The results of the FEM analyses, expressed as the distribution of Von Mises stress values, has allowed us to conclude that (i) fibreglass‐reinforced composite distributes stress better than titanium alloy or stainless steel; (ii) fibreglass‐reinforced composite posts should be inserted as deeply as possible (but maintaining 5–6 mm of gutta‐percha apical seal); (iii) fibreglass‐reinforced composite post diameter does not affect stress distribution, therefore, as much radicular dentin as possible should be preserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Can Fiber Posts Increase Root Stresses and Reduce Fracture?
Santos, A. F. V., Meira, J. B. C., Tanaka, C. B., Xavier, T. A., Ballester, R. Y., Lima, R. G., Pfeifer, C. S., & Versluis, A. (2010) · Journal of Dental Research · doi:10.1177/0022034510363382 · Cited by 161
Cicciù, M., Cervino, G., Bramanti, E., Lauritano, F., Lo Gudice, G., Scappaticci, L., Rapparini, A., Guglielmino, E., & Risitano, G. (2015) · Computational and Mathematical Methods in Medicine · doi:10.1155/2015/943839 · Cited by 86
FEM and VonMises analyses of different dental implant shapes for masticatory loading distribution
CICCI�, M. (2014) · Oral & Implantology · doi:10.11138/orl/2014.7.1.001 · Cited by 62
“This justifies, in part, the decision of Brand Production of replacing this model after a few years since the introduction in the market with a new “D model” concerned with a neck design completely different shape (24-26).”
BackgroundHasegawa, A., Shinya, A., Nakasone, Y., Lassila, L. V. J., Vallittu, P. K., & Shinya, A. (2010) · International Journal of Biomaterials · doi:10.1155/2010/659802 · Cited by 27
Metadata
- Authors
- BOSCHIAN PEST, L., GUIDOTTI, S., PIETRABISSA, R., & GAGLIANI, M.
- Venue
- Journal of Oral Rehabilitation
- Publisher
- Wiley
- Published
- 2006-08-08
- Volume
- 33
- Issue
- 9
- Pages
- 690-697
- ISSN
- 0305-182X (ISSN-L)
- 1365-2842
- OpenAlex
- W2052924372
- Cited by
- 118
- References
- 0
- FWCI
- 11.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.