Development of 3D CAD/FEM Analysis System for Natural Teeth and Jaw Bone Constructed from X-Ray CT Images
Open accessAbstract
A three-dimensional finite element model of the lower first premolar, with the three layers of enamel, dentin, and pulp, and the mandible, with the two layers of cortical and cancellous bones, was directly constructed from noninvasively acquired CT images. This model was used to develop a system to analyze the stresses on the teeth and supporting bone structure during occlusion based on the finite element method and to examine the possibility of mechanical simulation.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The attributes of linear, homogeneous, continuous, isotropic materials and a semicontrolled mesh with high-order tetrahedral elements are commonly used in biomodelling and numerical analysis on biological tissues and organs.
“All these attributes are commonly used when performing biomodelling and numerical analysis on biological tissues and organs [22, 37, 43–50].”
From Numerical Analysis of the ACL, with Sprains of Different Degrees after Trauma (2021) · cites this paper as [49]
Materials and Methods §§2.3–2.5 (pages unavailable) describe a linearly elastic bone model, specified mesh sizes, and tetrahedral elements. But §2.4 identifies the elements as four-node tetrahedra, not high-order elements; the paper also does not establish that the full set of stated material and mesh attributes is commonly used across biological tissues and organs. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Stiffness and Deflection Analysis of Complex Structures
TURNER, M. J., Clough, R. W., Martin, H. C., et al. (1956) · Journal of the aeronautical sciences. [REQUEST TITLE] · doi:10.2514/8.3664 · Cited by 1,572 · see citing works
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283 · see citing works
Finite element analysis of a glass fibre reinforced composite endodontic post
Pegoretti, A., Fambri, L., Zappini, G., et al. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00407-0 · Cited by 431 · see citing works
Bartlett, D. W., & Shah, P. (2006) · Journal of Dental Research · doi:10.1177/154405910608500405 · Cited by 399 · see citing works
Sevimay, M., Turhan, F., Kılıçarslan, M. A., et al. (2005) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2004.12.019 · Cited by 358 · see citing works
Dose reduction in maxillofacial imaging using low dose Cone Beam CT
Tsiklakis, K., Donta, C., Gavalá, S., et al. (2005) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.05.011 · Cited by 327 · see citing works
Trabecular bone exhibits fully linear elastic behavior and yields at low strains
Keaveny, T. M., Guo, X.-D. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90053-1 · Cited by 300 · see citing works
Measurement of Stress in Mastication. I
Anderson, D. J. (1956) · Journal of Dental Research · doi:10.1177/00220345560350050201 · Cited by 278 · see citing works
Efficient 3D finite element analysis of dental restorative procedures using micro-CT data
Magne, P. (2006) · Dental Materials · doi:10.1016/j.dental.2006.03.013 · Cited by 257 · see citing works
Eskitaşçıoğlu, G., Üşümez, A., Sevimay, M., et al. (2004) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2003.10.018 · Cited by 252 · see citing works
Biomechanical aspects of two different implant-prosthetic consepts for edentulous maxillae
Benzing, U., Gall, H., & Weber, H. (1995) · Implant Dentistry · doi:10.1097/00008505-199500440-00024 · Cited by 167 · see citing works
Photoelasticity as a Research Technique for Analyzing Stresses in Dental Structures
Mahler, D. B., & Peyton, F. A. (1955) · Journal of Dental Research · doi:10.1177/00220345550340060601 · Cited by 130 · see citing works
Stresses at the cervical lesion of maxillary premolar—a finite element investigation
Lee, H.-T., Lin, C. L., Wang, C.-Y., et al. (2002) · Journal of Dentistry · doi:10.1016/s0300-5712(02)00020-9 · Cited by 130 · see citing works
The Role of the Finite Element Model in Dental Implants
DeTolla, D. H., Andreana, S., Patra, A., et al. (2000) · Journal of Oral Implantology · doi:10.1563/1548-1336(2000)026 · Cited by 127 · see citing works
Tanne, K., Hiraga, J., Kakiuchi, K., et al. (1989) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/0889-5406(89)90050-4 · Cited by 127 · see citing works
Measurement of Stress in Mastication. II
Anderson, D. J. (1956) · Journal of Dental Research · doi:10.1177/00220345560350050301 · Cited by 123 · see citing works
Stress distribution in a post‐restored tooth using the three‐dimensional finite element method
Pest, L. B., GUIDOTTI, S., Pietrabissa, R., et al. (2006) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2006.01538.x · Cited by 118 · see citing works
Jeon, P. D., Turley, P. K., Moon, H. B., et al. (1999) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(99)70328-8 · Cited by 109 · see citing works
Miller, W. D. (1907) · Medical Entomology and Zoology · Cited by 109 · see citing works
Zarone, F., Apicella, A. M., Nicolais, L., Aversa, R. M., & Sorrentino, R. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.140114.x · Cited by 108 · see citing works
Cibirka, R., Razzoog, M. E., Lang, B. R., et al. (1992) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(92)90247-8 · Cited by 107 · see citing works
Helldén, L. B., & Dérand, T. (1998) · PubMed · Cited by 95 · see citing works
In vivo horizontal bending moments on implants.
Richter, E. (1998) · PubMed · Cited by 84 · see citing works
Falk, H., Laurell, L., & Lundgren, D. (1989) · PubMed · Cited by 78 · see citing works
Hirabayashi, M., Motoyoshi, M., 石丸, 透., et al. (2002) · Journal of Oral Science · doi:10.2334/josnusd.44.1 · Cited by 31 · see citing works
Haut, T. L., Hull, M. L., & Howell, S. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00049-9 · Cited by 31 · see citing works
Yokoyama, D., Shinya, A., Lassila, L. V. J., et al. (2009) · PubMed · Cited by 17 · see citing works
Self-citationNAKASONE, Y., Kita, S., Hasegawa, A., et al. (2008) · Keisan Rikigaku Koenkai koen ronbunshu/Keisan Rikigaku Kouenkai kouen rombunshuu · doi:10.1299/jsmecmd.2008.21.628 · Cited by 2 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 3
- [21]Shinya A Matsuda T Nakasone Y Shinya A Hybrid resin fixed partial dentures reinforced with glass fiber-Optimum posterior fiber frame design with finite element analysis Journal of the Japanese Society for Dental Materials and Devices 2004 23 186 192
- [25]Hasegawa A Nakasone Y Shinya A Lassila LVJ Vallittu PK Shinya A Accuracy of three-dimensional finite element model of artificial object using dental cone beam computed tomography systems The Journal of Contemporary Dental Practice. In press
- [29]Black GVA Work on Operative Dentistry 1917 1 3rd edition Chicago, Ill, USA Medicodental
Cited by
Sorted by citations
Numerical Analysis of the ACL, with Sprains of Different Degrees after Trauma
Marquet-Rivera, R. A., Urriolagoitia-Sosa, G., Romero-Ángeles, B., Hernández-Vázquez, R. A., Mastache-Miranda, O. A., Cruz-López, S., Torres-Yáñez, A., & Urriolagoitia-Calderón, G. (2021) · Computational and Mathematical Methods in Medicine · doi:10.1155/2021/2109348 · Cited by 5 · see citing works
Hernández-Vázquez, R. A., Marquet-Rivera, R. A., Mastache-Miranda, O. A., Vázquez-López, A. J., Cruz-López, S., & Vázquez-Feijoo, J. A. (2021) · Applied Bionics and Biomechanics · doi:10.1155/2021/6658039 · Cited by 4 · see citing works
- Authors
- Hasegawa, A., Shinya, A., Nakasone, Y., Lassila, L. V. J., Vallittu, P. K., & Shinya, A.
- Affiliations
- Nippon Dental University (JP)
- University of Turku (FI)
- Tokyo University of Science (JP)
- Corresponding author
- Hasegawa, Aki
- Venue
- International Journal of Biomaterials
- Publisher
- Hindawi Limited
- Published
- 2010
- Volume
- 2010
- Pages
- 1-7
- ISSN
- 1687-8787 (ISSN-L)
- 1687-8795
- PMC
- PMC2913519
- OpenAlex
- W2076119876
- Cited by
- 27
- References
- 28
- Citations by year
- 2025: 1 · 2024: 2 · 2021: 4 · 2020: 3 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 2 · 2014: 3 · 2013: 5
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- International Journal of Biomaterials (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Dentistry › Orthodontics › Dental materials and restorations
- Health Sciences › Dentistry › Oral Surgery › Dental Radiography and Imaging
- Health Sciences › Dentistry › Orthodontics › Orthodontics and Dentofacial Orthopedics
- Keywords
- natural teeth, mandible, finite element model, enamel, dentin, dental pulp, cortical bone, trabecular bone, occlusal stress, mechanical simulation, 3D CAD
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review