CoChat

Inter‐observer reproducibility and analysis of gastric volume measurements and gastric emptying assessed with magnetic resonance imaging

Fruehauf, H., Menne, D., Kwiatek, M. A., Forras‐Kaufman, Z., Kaufman, E., Goetze, O., Fried, M., Schwizer, W., Fox, M. · 2011 · Neurogastroenterology & Motility
Cited by 54

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background Magnetic resonance (MR) imaging provides direct, non‐invasive measurements of gastric function and emptying. The inter‐observer variability (IOV) of MR volume measurements and the most appropriate analysis of MR data have not been established. To assess IOV of total gastric volume (TGV) and gastric content volume (GCV) measurements from MR images and the ability of standard power exponential (PowExp), and a novel linear exponential (LinExp) model to describe MR data. Methods Ten healthy volunteers received three different volumes of a liquid nutrient test meal (200–800 mL) on 3 days in a randomized order. Magnetic resonance scans were acquired using a 1.5T system every 1–5 min for 60 min. Total gastric volume and GCV were measured independently by three observers. Volume data were fitted by PowExp and LinExp models to assess postprandial volume change and gastric emptying half time (T50). Key Results An initial rise in GCV and TGV was often observed after meal ingestion, thereafter GCV and TGV decreased in an approximately linear fashion. Inter‐observer variability decreased with greater volumes from 12% at 200 mL to 6% at 600 and 800 mL. Inter‐observer variability for T50 was <5%. PowExp and LinExp models provided comparable estimates of T50; however, only LinExp described dynamic volume change in the early postprandial period. Conclusions & Inferences Gastric MR provides quantitative measurements of postprandial volume change with low IOV, unless the stomach is nearly empty. The novel LinExp model describes the dynamic volume changes in the early postprandial period more accurately than the PowExp model used in existing gastric emptying studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2982.2011.01743.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 54

Metadata

Authors
Fruehauf, H., Menne, D., Kwiatek, M. A., Forras‐Kaufman, Z., Kaufman, E., Goetze, O., Fried, M., Schwizer, W., & Fox, M.
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
2011-07-11
Volume
23
Issue
9
Pages
854-861
ISSN
  • 1350-1925 (ISSN-L)
  • 1365-2982
OpenAlex
W1595061245
Cited by
54
References
2
FWCI
2.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inter‐observer reproducibility and analysis of gastric volume measurements and gastric emptying assessed with magnetic resonance imaging. https://app.cochat.ai/papers/10.1111/j.1365-2982.2011.01743.x
The paper
Fruehauf, H., Menne, D., Kwiatek, M. A., Forras‐Kaufman, Z., Kaufman, E., Goetze, O., Fried, M., Schwizer, W., & Fox, M. (2011). Inter‐observer reproducibility and analysis of gastric volume measurements and gastric emptying assessed with magnetic resonance imaging. Neurogastroenterology & Motility. https://doi.org/10.1111/j.1365-2982.2011.01743.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.