CoChat

Presence of viable mould propagules in indoor air in relation to house damp and outdoor air

Open access
Verhoeff, A. P., van Wijnen, J. H., Brunekreef, B., Fischer, P., van Reenen‐Hoekstra, E. S., Samson, R. A. · 1992 · Allergy
Cited by 108

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The presence of viable mould propagules in indoor air was investigated using the N6‐Andersen sampler in combination with DG18‐agar, in relation to house damp (characterized with a checklist) and in relation to the presence of moulds in outdoor air. The first part of the study was conducted in 46 houses in the autumn of 1987, the second part in 84 houses in May 1989. Further, in the second part, the results obtained with settlement plates (OPD) were compared with those obtained with the N6‐Andersen sampler. The number of CFU/m 3 in the indoor and outdoor air varied widely. A large variety of mould genera and species was isolated. Species of Cladosporium, Penicillium and Wallemia predominated. The variability in time was high and the reproducibility of the measurements in terms of CFU/m 3 and of species isolated was only moderate. The low predictive value of these measurements limits their use in epidemiological studies of the relationship between exposure to moulds and respiratory symptoms. Overall, the geometric mean concentration was somewhat higher outdoors than indoors. However, the clear differences found between the number of CFU/m 3 belonging to different mould species in in‐ and outdoor air show that the presence of viable mould propagules in indoor air is not simply a reflection of the presence of moulds in outdoor air. The presence of moulds in indoor air was only weakly related to house damp as characterized by the checklist. High, statistically significant correlations were found between the CFU yield obtained with the OPD and the CFU/m 3 yield obtained with the N6‐Andersen sampler. However, the number of species isolated with the OPD was significantly lower than that obtained with the N6‐Andersen sampler.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1398-9995.1992.tb05093.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 108

Metadata

Authors
Verhoeff, A. P., van Wijnen, J. H., Brunekreef, B., Fischer, P., van Reenen‐Hoekstra, E. S., & Samson, R. A.
Venue
Allergy
Publisher
Wiley
Published
1992-04
Volume
47
Issue
2PART1
Pages
83-91
ISSN
  • 0105-4538 (ISSN-L)
  • 1398-9995
OpenAlex
W1979888329
Cited by
108
References
1
FWCI
6.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Presence of viable mould propagules in indoor air in relation to house damp and outdoor air. https://app.cochat.ai/papers/10.1111/j.1398-9995.1992.tb05093.x
The paper
Verhoeff, A. P., van Wijnen, J. H., Brunekreef, B., Fischer, P., van Reenen‐Hoekstra, E. S., & Samson, R. A. (1992). Presence of viable mould propagules in indoor air in relation to house damp and outdoor air. Allergy. https://doi.org/10.1111/j.1398-9995.1992.tb05093.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.