Extracorporeal (“ex vivo”) connection of pig kidneys to humans. I. Clinical data and studies of platelet destruction
The DOI matches its Crossref record.
Abstract
The pioneering experiment by Welsh et al. (Immunological Lett 1991:29:167–170) connecting a pig kidney to the human circulation has been repeated in a modified manner. Two volunteer dialysis patients were pretreated by daily plasmapheresis on days ‐2,‐1, and 0 to remove the naturally occurring anti‐pig xenoantibodies. The anti‐pig lymphocytotoxic liters were reduced from 1:8 to 1:2 in patient 1 and from 1:8 to 1:1 in patient 2. No steroids or immunosuppressive drugs were administrated before or during the experiments. A sterile pig kidney was extracorporeally (“ex vivo”) connected to the patients a/v fistula using an arterial and a venous pump similar to a dialysis. The two experiments gave different results. In the first experiment the perfusion pressure was kept at 100 mmHg for the initial 25 min by reducing the pump speed until the minimum blood flow of 30 ml/min was reached. Thereafter, the pressure rose continuously and the experiment was terminated at 65 min at a perfusion pressure of 200 mmHg. The patient did not feel any discomfort during the perfusion. In the second experiment, a stable blood flow of 200 ml/min was reached at a pressure of 100 mmHg after a few minutes. The perfusion was terminated at 15 min when the patient developed chest and abdominal pain, hypotension, and electrocardiographic signs of myocardial ischemia. The patient recovered quickly. In the first experiment, small volumes of clear urine was produced until the pressure rose above 100 mmHg, which resulted in hematuria. In the second experiment clear urine (4 ml/min) was produced. 51 Chromium clearance values were after 15 min <1 ml/min for kidney 1 and 12 ml/min (8 ml/min/100 g) for kidney 2. A drastic reduction in platelet count (128 to 48 and 64 to 8 × 10 9/1, respectively) during the passage through the kidney was found in blood samples collected simultaneously before and after the organ. No change in hemoglobin values and leucocyte counts were found. Light‐ and electron‐microscopical analysis of the kidney tissues revealed for kidney 1 focal areas with obliteration of the glomerular and peritubular capillaries by platelets and PMN cells and severe damage of the endothelial cells comparable to a picture of a hyperacute rejection. In kidney 2, all vessels were patent but in the capillaries large amount of membrane fragments were detected by electron microscopy and a discrete damage of the endothelial cells were seen in some segments. No intact platelets were present in the vascular tree. These human experiments support the hypothesis that hyperacute rejection of pig to human xenografts is delayed in time by removal of the preformed anti‐pig xenoantibodies. A new finding was a very rapid destruction of platelets occurring in the kidney of patient 2 who had very low liters of xenoantibodies. The humoral immune response is described in detail in an accompanying paper (Rydberg et al., this issue).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Paradis, K., Langford, G., Long, Z., Heneine, W., Sandstrom, P., Switzer, W. M., Chapman, L. E., Lockey, C., Onions, D., The XEN 111 Study Group, et al. (1999) · Science · doi:10.1126/science.285.5431.1236 · Cited by 729
Results of Two Cases of Pig-to-Human Kidney Xenotransplantation
Montgomery, R. A., Stern, J. M., Lonze, B. E., Tatapudi, V. S., Mangiola, M., Wu, M., Weldon, E., Lawson, N., Deterville, C., Dieter, R. A., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2120238 · Cited by 508
Porcine Xenografts in Parkinson's Disease and Huntington's Disease Patients: Preliminary Results
Fink, J. S., Schumacher, J. M., Ellias, S. L., Palmer, E. P., Saint-Hilaire, M., Shannon, K., Penn, R., Starr, P., Vanhorne, C., Kott, H. S., et al. (2000) · Cell Transplantation · doi:10.1177/096368970000900212 · Cited by 232
“Pigs have been used as a source of t ransplantable tis sue for heart valves, pancreat ic islet cell t ransplants, skin grafts, and extracorporeal k idney and liver perfusion (4,6,16,41).”
BackgroundMethodInfection Barriers to Successful Xenotransplantation Focusing on Porcine Endogenous Retroviruses
Denner, J., & Tönjes, R. R. (2012) · Clinical Microbiology Reviews · doi:10.1128/cmr.05011-11 · Cited by 208
Factors in Xenograft Rejection
ROBSON, S. C., AM ESCH, J. S., & BACH, F. H. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb08509.x · Cited by 71
Metadata
- Authors
- Breimer, M. E., Björck, S., Svalander, C. T., Bengtsson, A., Rydberg, L., Lie‐Karlsen, K., Attman, P., Aurell, M., & Samuelsson, B. E.
- Venue
- Xenotransplantation
- Publisher
- Wiley
- Published
- 1996-11
- Volume
- 3
- Issue
- 4
- Pages
- 328-339
- ISSN
- 0908-665X (ISSN-L)
- 1399-3089
- OpenAlex
- W2138130460
- Cited by
- 55
- References
- 0
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extracorporeal (“ex vivo”) connection of pig kidneys to humans. I. Clinical data and studies of platelet destruction. https://app.cochat.ai/papers/10.1111/j.1399-3089.1996.tb00155.x
- The paper
- Breimer, M. E., Björck, S., Svalander, C. T., Bengtsson, A., Rydberg, L., Lie‐Karlsen, K., Attman, P., Aurell, M., & Samuelsson, B. E. (1996). Extracorporeal (“ex vivo”) connection of pig kidneys to humans. I. Clinical data and studies of platelet destruction. Xenotransplantation. https://doi.org/10.1111/j.1399-3089.1996.tb00155.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.