Statistical aspects in studies of preoperative fluid intake and gastric content
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Twelve randomised studies of preoperative intake of clear fluids and gastric content were reviewed and presented together with a separate study performed by the authors. A common deficiency in design was the omission of detailed information concerning randomisation procedures, distribution of data, and choice of statistical methods. Only one reviewed study included power calculations and only 3 reported 95% C.I. (Confidence Intervals). Deficiencies in design and data collection rendered the conclusion of two studies invalid. Incorrect use of statistical tests in some of the remaining studies may have resulted in non‐significant differences becoming statistically significant. This, however, did not change the main conclusion of a meta‐analysis that intake of clear fluids up to 2 hours before general Anaesthesia was safe as fluid intake either decreased or had no effect on gastric fluid volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CONSORT statement: extension to cluster randomised trials
Campbell, M. K., Elbourne, D. R., & Altman, D. G. (2004) · BMJ · doi:10.1136/bmj.328.7441.702 · Cited by 2,557
The scandal of poor medical research.
Altman, D. G. (1994) · BMJ · doi:10.1136/bmj.308.6924.283 · Cited by 897
Cited by
Smith, I., Kranke, P., Murat, I., Smith, A., OʼSullivan, G., Sreide, E., Spies, C., & in’t Veld, B. (2011) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e3283495ba1 · Cited by 1,053
Self-citationPreoperative fasting for adults to prevent perioperative complications
Brady, M. C., Kinn, S., Stuart, P., & Ness, V. (2003) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004423 · Cited by 694
Local anaesthetic thoracoscopy: British Thoracic Society pleural disease guideline 2010
Rahman, N. M., Ali, N. J., Brown, G., Chapman, S. J., Davies, R. J. O., Downer, N. J., Gleeson, F. V., Howes, T. Q., Treasure, T., Singh, S., et al. (2010) · Thorax · doi:10.1136/thx.2010.137018 · Cited by 392
Ljungqvist, O., & Søreide, E. (2003) · British Journal of Surgery · doi:10.1002/bjs.4066 · Cited by 290
Self-citationPre‐operative fasting guidelines: an update
Søreide, E., Eriksson, L. I., Hirlekar, G., Eriksson, H., Henneberg, S. W., Sandin, R., Raeder, J., & (Task Force on Scandinavian Pre‐operative Fasting Guidelines, C. P. C. S. S. O. A. A. I. C. M. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00781.x · Cited by 270
Self-citation
Metadata
- Authors
- Søreide, E., Strømskag, K. E., & Steen, P. A.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 1995-08
- Volume
- 39
- Issue
- 6
- Pages
- 738-743
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W2008212018
- Cited by
- 55
- References
- 2
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Statistical aspects in studies of preoperative fluid intake and gastric content. https://app.cochat.ai/papers/10.1111/j.1399-6576.1995.tb04162.x
- The paper
- Søreide, E., Strømskag, K. E., & Steen, P. A. (1995). Statistical aspects in studies of preoperative fluid intake and gastric content. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/j.1399-6576.1995.tb04162.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.