Bio‐/haemocompatibility: implications and outcomes for sensors?
The DOI matches its Crossref record.
Abstract
Sensors are a sample contacting technology, and when exposed to biological matrices tend to suffer from the problem of poor biocompatibility and surface fouling. The effects are evidenced by time dependant signal drift (particularly for those devices which are implanted intravascularly). Practical methods to reduce such effects require an understanding of the interface between the electrode and its environment prior to assessment of the potential areas for improvement. Current procedures employed to overcome the observed losses in electrode sensitivity (following exposure to whole blood) include surface modification of the outer diffusion limiting membrane (via variation in film porosity) or even biomimicry of the fluid cell membrane. At amperometric electrodes incorporation of additional inner perm‐selective membranes has achieved a reduction in electrode passivation from undesirable surface active compounds as has the use of low polarisation potentials. Other studies have attempted to induce an aqueous barrier between the matrix and the electrode tip which physically prevents passage of cellular components from the sensor surface. Careful choice of the system and materials will ultimately lead to biocompatible non‐fouling devices capable of functioning in an array of bio‐environments suitable for clinical monitoring of the critically ill patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
“tissue is directly related to the blood glucose concentration ( 80 ).”
BackgroundInfluentialMethods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
In vivo studies of polypyrrole/peptide coated neural probes
Cui, X. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00415-5 · Cited by 505
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 418
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Metadata
- Authors
- KYROLAINEN, M., RIGSBY, P., EDDY, S., & VADGAMA, P.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 1995-03
- Volume
- 39
- Issue
- s104
- Pages
- 55-60
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W2042151380
- Cited by
- 41
- References
- 0
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bio‐/haemocompatibility: implications and outcomes for sensors? https://app.cochat.ai/papers/10.1111/j.1399-6576.1995.tb04255.x
- The paper
- KYROLAINEN, M., RIGSBY, P., EDDY, S., & VADGAMA, P. (1995). Bio‐/haemocompatibility: implications and outcomes for sensors? Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/j.1399-6576.1995.tb04255.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.