CoChat

Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post‐operative cardiac surgery patients in Germany: results from a postal survey

Kastrup, M., Markewitz, A., Spies, C., Carl, M., Erb, J., Große, J., Schirmer, U. · 2007 · Acta Anaesthesiologica Scandinavica
Cited by 163

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

Background: In Germany, more than 100,000 patients are monitored and treated in 80 intensive care units (ICUs) following cardiac surgery each year. The controversies concerning the different methods of hemodynamic monitoring and the appropriate agents for volume therapy and inotropic support are well known. However, little is known about how monitoring and treatment are currently performed. Methods: A questionnaire with 39 questions was sent to the leading physicians of 80 ICUs in Germany, treating patients after cardiac surgery. The questions to be answered covered the current practice of hemodynamic monitoring, volume replacement, inotropic/vasopressor support and transfusions in patients after cardiac surgery. Results: Sixty‐nine per cent of the questionnaires were completed and returned. All ICUs used basic monitoring as recommended by the societies. The use of advanced hemodynamic monitoring included the pulmonary artery catheter (58.2%), transesophageal echocardiography (38.1%) and transpulmonary dilution techniques (13%). Crystalloids (21.2%) and colloids (73%) were used for volume replacement. Epinephrine (41.8%) and dobutamine (30.9%) were the first‐choice inotropic drugs for the treatment of low cardiac output syndrome, followed by phosphodiesterase inhibitors (14.5%). Second‐choice drugs for the treatment of low cardiac output syndrome were enoximone (29%), milrinone (25%) and dobutamine (25%). A written transfusion protocol and a transfusion threshold for red blood cells existed in 59% and 79% of ICUs, respectively. Conclusion: Hemodynamic monitoring and the variability in clinical practice with regard to volume replacement, transfusion triggers and the use of vasopressors/inotropes in cardiac surgery patients tend to follow the results of traditional experience rather than current scientific knowledge. Guidelines are therefore necessary to help to improve the standards of intensive care after cardiac surgery and thus the outcome of patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1399-6576.2006.01190.x

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 37 references

Cited by

See all 163

Metadata

Authors
Kastrup, M., Markewitz, A., Spies, C., Carl, M., Erb, J., Große, J., & Schirmer, U.
Venue
Acta Anaesthesiologica Scandinavica
Publisher
Wiley
Published
2006-11-10
Volume
51
Issue
3
Pages
347-358
ISSN
  • 0001-5172 (ISSN-L)
  • 1399-6576
OpenAlex
W2125568275
Cited by
163
References
37
FWCI
3.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post‐operative cardiac surgery patients in Germany: results from a postal survey. https://app.cochat.ai/papers/10.1111/j.1399-6576.2006.01190.x
The paper
Kastrup, M., Markewitz, A., Spies, C., Carl, M., Erb, J., Große, J., & Schirmer, U. (2007). Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post‐operative cardiac surgery patients in Germany: results from a postal survey. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/j.1399-6576.2006.01190.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.