Microparticle sizing by dynamic light scattering in fresh‐frozen plasma
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background We have previously shown that fresh‐frozen plasma (FFP) contains red blood cell‐derived procoagulant microparticles (MPs) that are removable by 0·2 µm filtration. Given the limitations of current methods for accurately sizing MPs, we have applied the novel approach of dynamic light scattering (DLS) to characterize the size distributions of these MPs within FFP. Methods Fresh‐frozen plasma was prepared from blood Group A and O donations (n = 10 of each) after an overnight hold of whole blood at 4°C. On the day of analysis, plasma was thawed to 37°C and daughter aliquots were studied pre‐ and post‐filtration (0·2 µm filtration device, Ceveron® MFU‐500, Technoclone). MP size and dispersity was assessed using a Zetasizer Nano S (Malvern Instruments Ltd), which employs a 173° backscatter detector and an N5 Submicron Particle Size Analyser (Beckman Coulter) using multi‐angle measurements (30·1°, 62·6° and 90°). The analysers presented MP size distribution graphically as intensity plots, mean size, standard deviation and polydispersity index. Results Of the instruments used, only the N5 utilizing a 30·1° angle of measurement could detect MPs of the expected size distribution and demonstrate their removal by filtration. MPs (range of mean particle diameters: pre, 101–464 nm; post, 21–182 nm filtration) were significantly smaller post‐filtration (P < 0·0001), but polydispersity index (median: pre, 0·746, post, 0·769) exhibited no significant change. There was no significant difference between the size of MPs from blood Group O (pre, 247 nm) and Group A (pre, 289 nm) samples (P = 0·44). Conclusion Our data demonstrates that DLS offers a novel approach to assessing MP size and distribution, a technique that could be easily adopted as a means of assessing MPs within either FFP or other blood products.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The characterization and impact of microparticles on haemostasis within fresh‐frozen plasma
Lawrie, A. S., Harrison, P., Cardigan, R. A., & Mackie, I. J. (2008) · Vox Sanguinis · doi:10.1111/j.1423-0410.2008.01081.x · Cited by 64
Self-citationThe dynamics of clot formation in fresh‐frozen plasma
Lawrie, A. S., Cardigan, R. A., Williamson, L. M., Machin, S. J., & Mackie, I. J. (2008) · Vox Sanguinis · doi:10.1111/j.1423-0410.2008.01037.x · Cited by 41
Self-citation
Cited by
Membrane vesicles, current state-of-the-art: emerging role of extracellular vesicles
György, B., Szabó, T. G., Pásztói, M., Pál, Z., Misják, P., Aradi, B., László, V., Pállinger, É., Pap, E., Kittel, Á., et al. (2011) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-011-0689-3 · Cited by 2,074
New Technologies for Analysis of Extracellular Vesicles
Shao, H., Im, H., Castro, C. M., Breakefield, X., Weissleder, R., & Lee, H. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00534 · Cited by 1,675
Sizing and phenotyping of cellular vesicles using Nanoparticle Tracking Analysis
Dragovic, R. A., Gardiner, C., Brooks, A. S., Tannetta, D. S., Ferguson, D. J. P., Hole, P., Carr, B., Redman, C. W. G., Harris, A. L., Dobson, P. J., et al. (2011) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2011.04.003 · Cited by 1,362
Self-citationGurunathan, S., Kang, M.-H., Jeyaraj, M., Qasim, M., & Kim, J.-H. (2019) · Cells · doi:10.3390/cells8040307 · Cited by 1,122
The Methods of Choice for Extracellular Vesicles (EVs) Characterization
Szatanek, R., Baj-Krzyworzeka, M., Zimoch, J., Lekka, M., Siedlar, M., & Baran, J. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18061153 · Cited by 563
Optical and non‐optical methods for detection and characterization of microparticles and exosomes
VAN DER POL, E., HOEKSTRA, A. G., STURK, A., OTTO, C., VAN LEEUWEN, T. G., & NIEUWLAND, R. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04074.x · Cited by 535
D'Souza-Schorey, C., & Clancy, J. W. (2012) · Genes & Development · doi:10.1101/gad.192351.112 · Cited by 528
Technologies and Standardization in Research on Extracellular Vesicles
Gandham, S., Su, X., Wood, J., Nocera, A. L., Alli, S. C., Milane, L., Zimmerman, A., Amiji, M., & Ivanov, A. R. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.05.012 · Cited by 494
Integrated Magneto–Electrochemical Sensor for Exosome Analysis
Jeong, S., Park, J., Pathania, D., Castro, C. M., Weissleder, R., & Lee, H. (2016) · ACS Nano · doi:10.1021/acsnano.5b07584 · Cited by 469
György, B., Módos, K., Pállinger, É., Pálóczi, K., Pásztói, M., Misják, P., Deli, M. A., Sipos, Á., Szalai, A., Voszka, I., et al. (2011) · Blood · doi:10.1182/blood-2010-09-307595 · Cited by 409
Exosomes and microvesicles in normal physiology, pathophysiology, and renal diseases
Ståhl, A.-L., Johansson, K., Mossberg, M., Kahn, R., & Karpman, D. (2019) · Pediatric Nephrology · doi:10.1007/s00467-017-3816-z · Cited by 356
Microglial-derived microparticles mediate neuroinflammation after traumatic brain injury
Kumar, A., Stoica, B. A., Loane, D. J., Yang, M., Abulwerdi, G., Khan, N., Kumar, A., Thom, S. R., & Faden, A. I. (2017) · Journal of Neuroinflammation · doi:10.1186/s12974-017-0819-4 · Cited by 319
Cong, M., Tan, S., Li, S., Gao, L., Huang, L., Zhang, H.-G., & Qiao, H. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.114108 · Cited by 302
Samaeekia, R., Rabiee, B., Putra, I., Shen, X., Park, Y. J., Hematti, P., Eslani, M., & Djalilian, A. R. (2018) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-24803 · Cited by 281
Pre-analytical and analytical issues in the analysis of blood microparticles
Yuana, Y., Bertina, R., & Osanto, S. (2011) · Thrombosis and Haemostasis · doi:10.1160/th10-09-0595 · Cited by 268
Innovation in detection of microparticles and exosomes
van der Pol, E., Coumans, F., Varga, Z., Krumrey, M., & Nieuwland, R. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12254 · Cited by 250
Circulating microparticles: square the circle
Barteneva, N. S., Fasler-Kan, E., Bernimoulin, M., Stern, J. N., Ponomarev, E. D., Duckett, L., & Vorobjev, I. A. (2013) · BMC Cell Biology · doi:10.1186/1471-2121-14-23 · Cited by 245
“However, filtration of MPs should be used with caution, since this procedure can lead to fragmentation of larger MPs [29].”
BackgroundMethodNanoparticle analysis of circulating cell-derived vesicles in ovarian cancer patients
Gercel-Taylor, C., Atay, S., Tullis, R. H., Kesimer, M., & Taylor, D. D. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2012.06.004 · Cited by 232
“Dynamic light scattering (DLS) can be used to measure these vesicles in suspension and determines size by light scattered from all vesicles under Brownian motion [21]; however, a major disadvantage is the inability to resolve mixtures of microvesicles and exosomes as well as biasing toward the detection of larger part…”
BackgroundRupert, D. L. M., Claudio, V., Lässer, C., & Bally, M. (2017) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2016.07.028 · Cited by 212
Burnouf, T., Goubran, H. A., Chou, M.-L., Devos, D., & Radosevic, M. (2014) · Blood Reviews · doi:10.1016/j.blre.2014.04.002 · Cited by 210
Extracellular vesicles as a drug delivery system: A systematic review of preclinical studies
Escudé Martinez de Castilla, P., Tong, L., Huang, C., Sofias, A. M., Pastorin, G., Chen, X., Storm, G., Schiffelers, R. M., & Wang, J.-W. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.05.011 · Cited by 208
Liu, H., Zhang, Q., Wang, S., Weng, W., Jing, Y., & Su, J. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.12.006 · Cited by 204
Advanced liquid biopsy technologies for circulating biomarker detection
Soda, N., Rehm, B. H. A., Sonar, P., Nguyen, N.-T., & Shiddiky, M. J. A. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb01490j · Cited by 198
Saluja, A., Fesinmeyer, R. M., Hogan, S., Brems, D. N., & Gokarn, Y. R. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.08.020 · Cited by 183
Preparation and characterization of extracellular vesicles
Tiwari, S., Kumar, V., Randhawa, S., & Verma, S. K. (2021) · American Journal of Reproductive Immunology · doi:10.1111/aji.13367 · Cited by 182
Brisson, A. R., Tan, S., Linares, R., Gounou, C., & Arraud, N. (2017) · Platelets · doi:10.1080/09537104.2016.1268255 · Cited by 179
“Using DLS, Lawrie et al. [35] reported that fresh frozen plasma EVs ranged from 100 to 500 nm, which is also close to our results.”
MethodResultRastogi, S., Sharma, V., Bharti, P. S., Rani, K., Modi, G. P., Nikolajeff, F., & Kumar, S. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22010440 · Cited by 174
“DLS is a simple and fast technique but its use is limited to homogenous populations of exosomes due to its biasness towards the presence of larger vesicles, hence it cannot be used for heterogeneous populations of exosomes and generally suffers from having lower resolution than NTA [76,77].”
BackgroundInfluentialExosomes and Microvesicles: Identification and Targeting By Particle Size and Lipid Chemical Probes
Kastelowitz, N., & Yin, H. (2014) · ChemBioChem · doi:10.1002/cbic.201400043 · Cited by 171
Robert, S., Lacroix, R., Poncelet, P., Harhouri, K., Bouriche, T., Judicone, C., Wischhusen, J., Arnaud, L., & Dignat-George, F. (2012) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.111.244616 · Cited by 163
Extracellular Vesicles in Modifying the Effects of Ionizing Radiation
Szatmári, T., Hargitai, R., Sáfrány, G., & Lumniczky, K. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20225527 · Cited by 52
Recent advances in microfluidic methods in cancer liquid biopsy
Iliescu, F. S., Poenar, D. P., Yu, F., Ni, M., Chan, K. H., Cima, I., Taylor, H. K., Cima, I., & Iliescu, C. (2019) · Biomicrofluidics · doi:10.1063/1.5087690 · Cited by 51
Metadata
- Authors
- Lawrie, A. S., Albanyan, A., Cardigan, R. A., Mackie, I. J., & Harrison, P.
- Venue
- Vox Sanguinis
- Publisher
- Wiley
- Published
- 2009-03-08
- Volume
- 96
- Issue
- 3
- Pages
- 206-212
- ISSN
- 0042-9007 (ISSN-L)
- 1423-0410
- OpenAlex
- W2025740589
- Cited by
- 213
- References
- 2
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.