Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 254

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Not every PRP‐gel is born equal Evaluation of growth factor availability for tissues through four PRP‐gel preparations: Fibrinet®, RegenPRP‐Kit®, Plateltex® and one manual procedure

Mazzucco, L., Balbo, V., Cattana, E., Guaschino, R., Borzini, P.·2009·Vox Sanguinis

Abstract

Background The rationale for using topical platelet gel therapy is to provide the healing tissues with concentrated platelet‐derived factors. Several systems are available to prepare platelet‐rich plasma (PRP) and from these, the platelet gel. These systems produce two‐ to six‐fold platelet and growth factor‐enriched concentrations. The bioavailability of growth factors in tissue healing depends on the amount of growth factors stored in platelets but a portion of these is lost during platelet manipulation. Very few data have been reported on the kinetics of growth factor release from PRP‐gels. The aim of this study is to assess the growth factor recovery and its bioavailability to tissues in four different PRP and PRP‐gel preparation techniques. Materials and methods Three commercially available devices (Fibrinet®, RegenPRP‐Kit®, Plateltex®) and one manual procedure (home made, HM) were evaluated with reference to resulting platelet concentration, growth factor content and the kinetics of growth factor release from gel. Results Platelet concentration increased from 1·65‐ to 4·4‐fold in comparison with whole blood initially used. The final platelet concentration (× 10 3/µl) was: Fibrinet 1358 ± 419, Regen 430 ± 109, HM 1196 ± 188, and Plateltex 1160 ± 164. A high variation (5‐ to 27‐fold) was found in growth factor concentration in relation to the method used and also a high variation in the kinetics of growth factor release from gels. Conclusions Similar methods for platelet gel preparation revealed different performances concerning growth factor recovery and the kinetics of its release from the gel. It is unclear whether these noticeable differences are important for clinical management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1423-0410.2009.01188.x

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 254

Metadata

Authors
Mazzucco, L., Balbo, V., Cattana, E., Guaschino, R., & Borzini, P.
Venue
Vox Sanguinis
Publisher
Wiley
Published
2009-07-10
Volume
97
Issue
2
Pages
110-118
ISSN
  • 0042-9007 (ISSN-L)
  • 1423-0410
OpenAlex
W2102895306
Cited by
254
References
26
FWCI
18.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Not every PRP‐gel is born equal Evaluation of growth factor availability for tissues through four PRP‐gel preparations: Fibrinet®, RegenPRP‐Kit®, Plateltex® and one manual procedure. https://app.cochat.ai/papers/10.1111/j.1423-0410.2009.01188.x
The paper
Mazzucco, L., Balbo, V., Cattana, E., Guaschino, R., & Borzini, P. (2009). Not every PRP‐gel is born equal Evaluation of growth factor availability for tissues through four PRP‐gel preparations: Fibrinet®, RegenPRP‐Kit®, Plateltex® and one manual procedure. Vox Sanguinis. https://doi.org/10.1111/j.1423-0410.2009.01188.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.