CoChat

IDENTIFICATION OF BLOOD PRESSURE CONTROL MECHANISMS BY POWER SPECTRAL ANALYSIS

Stauss, Harald M · 2007 · Clinical and Experimental Pharmacology and Physiology
Cited by 231

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

SUMMARY: Blood pressure and organ perfusion are controlled by a variety of cardiovascular control systems, such as the baroreceptor reflex and the renin–angiotensin system (RAS), and by local vascular mechanisms, such as shear stress‐induced release of nitric oxide (NO) from the endothelium and the myogenic vascular response. Deviations in arterial blood pressure from its set point activate these mechanisms in an attempt to restore blood pressure and/or secure organ perfusion. However, the response times at which different cardiovascular mechanisms operate differ considerably (e.g. blood pressure control by the RAS is slower than blood pressure control via the baroreceptor reflex). Owing to these different response times, some cardiovascular control systems affect blood pressure more rapidly and others more slowly. Thus, identifying the frequency components of blood pressure variability (BPV) by power spectral analysis can potentially provide important information on individual blood pressure control mechanisms. Evidence is presented that the RAS, catecholamines, endothelial‐derived NO and myogenic vascular function affect BPV at very low frequencies (0.02–0.2 Hz) and that low‐frequency (LF) BPV (0.2–0.6 Hz) is affected by sympathetic modulation of vascular tone and endothelial‐derived NO in rats. In humans, LF BPV (0.075–0.15 Hz) is affected by sympathetic modulation of vascular tone and myogenic vascular function. The impact of the RAS and endothelial‐derived NO on BPV in humans requires further investigation. In conclusion, power spectral analysis is a powerful diagnostic tool that allows identification of pathophysiological mechanisms contributing to cardiovascular diseases, such as hypertension, heart failure and stroke, because it can separate slow from fast cardiovascular control mechanisms. The limitation that some cardiovascular control mechanisms affect the same frequency components of BPV requires the combination of blood pressure spectral analysis with other techniques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1681.2007.04588.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 231

Metadata

Authors
Stauss, H. M.
Venue
Clinical and Experimental Pharmacology and Physiology
Publisher
Wiley
Published
2007-02-23
Volume
34
Issue
4
Pages
362-368
ISSN
  • 0305-1870 (ISSN-L)
  • 1440-1681
OpenAlex
W1489427667
Cited by
231
References
4
FWCI
4.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: IDENTIFICATION OF BLOOD PRESSURE CONTROL MECHANISMS BY POWER SPECTRAL ANALYSIS. https://app.cochat.ai/papers/10.1111/j.1440-1681.2007.04588.x
The paper
Stauss, H. M. (2007). IDENTIFICATION OF BLOOD PRESSURE CONTROL MECHANISMS BY POWER SPECTRAL ANALYSIS. Clinical and Experimental Pharmacology and Physiology. https://doi.org/10.1111/j.1440-1681.2007.04588.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.