Abstract

SUMMARY: Scintigraphy is the gold standard for measuring gastric emptying, but the use of radioactive isotopes can produce substantial irradiation. The [13 C]‐acetate/octanoic acid breath test is widely used as a non‐radioactive alternative. The half [13 CO 2] excretion time () is closely correlated with the scintigraphic half‐emptying time (). However, is consistently remote from , because the distribution of [13 CO 2] into the bicarbonate pool delays the respiratory excretion of the [13 C] marker, which has already been emptied from the stomach. The time for the distribution process should be adjusted to diminish the discrepancy between the results of the scintigraphic and breath tests. The Wagner–Nelson method provides an accurate profile of drug absorption. We have recently applied the Wagner–Nelson method to breath testing to adjust the time for [13 CO 2] distribution. In the present study, the [13 C]‐breath test with Wagner–Nelson analysis was compared with scintigraphy. Six female volunteers simultaneously underwent scintigraphy and the breath test on two occasions, either to measure gastric emptying of the liquid phase (16 kcal) or for that of the solid phase (214 kcal). Time–percentage gastric retention curves were generated by scintigraphy and the breath test with Wagner–Nelson analysis. The half‐emptying times were determined by interpolation from the scintigraphic curve () and the Wagner–Nelson curve (). was calculated by conventional curve‐fitting techniques. For liquid and solid emptying, the gastric retention curves generated by the Wagner–Nelson method were comparable to the scintigraphic retention curves. For the liquid, was significantly longer than (93.8 ± 7.3 vs 14.2 ± 9.3 min, respectively; P < 0.0001), as was also observed for the solid phase (147.8 ± 34.4 vs 35.3 ± 11.2 min, respectively; P < 0.0001). In contrast, no significant differences were found between and for the liquid (13.5 ± 5.0 vs 14.2 ± 9.3 min, respectively; P = 0.734) and the solid (45.8 ± 10.2 vs 35.3 ± 11.2 min, respectively; P = 0.051) phase. In conclusion, Wagner–Nelson analysis makes the [13 C]‐breath test comparable to scintigraphy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1681.2007.04624.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Medium-chain triglycerides: an update

    Bach, A., & Babayan, V. (1982) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/36.5.950 · Cited by 1,151 · cited 1×

    “The tendency was not observed in the liquid GE study, probably because acetate is absorbed more rapidly than octanoic acid.(13) Conversely, in the conventional breath test, the difference between”
    Background

Show all 1 references

Cited by

See all 79

Metadata

Authors
Sanaka, M., Nakada, K., Nosaka, C., & Kuyama, Y.
Venue
Clinical and Experimental Pharmacology and Physiology
Publisher
Wiley
Published
2007-06-18
Volume
34
Issue
7
Pages
641-644
ISSN
  • 0305-1870 (ISSN-L)
  • 1440-1681
OpenAlex
W2053688735
Cited by
79
References
1
FWCI
4.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: THE WAGNER–NELSON METHOD MAKES THE [13C]‐BREATH TEST COMPARABLE TO RADIOSCINTIGRAPHY IN MEASURING GASTRIC EMPTYING OF A SOLID/LIQUID MIXED MEAL IN HUMANS. https://app.cochat.ai/papers/10.1111/j.1440-1681.2007.04624.x
The paper
Sanaka, M., Nakada, K., Nosaka, C., & Kuyama, Y. (2007). THE WAGNER–NELSON METHOD MAKES THE [13C]‐BREATH TEST COMPARABLE TO RADIOSCINTIGRAPHY IN MEASURING GASTRIC EMPTYING OF A SOLID/LIQUID MIXED MEAL IN HUMANS. Clinical and Experimental Pharmacology and Physiology. https://doi.org/10.1111/j.1440-1681.2007.04624.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.