FLUID MECHANICS OF ARTIFICIAL HEART VALVES
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
SUMMARY: Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged‐ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue‐based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non‐physiological blood flow patterns. In the present review, we provide a bird's‐eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life‐long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Biodegradable polymeric scaffolds for musculoskeletal tissue engineering
Agrawal, C. M., & Ray, R. B. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<141::aid-jbm1000>3.0.co;2-j · Cited by 1,052
Human Physiology: An Integrated Approach
Silverthorn, D. U. (1997) · Cited by 628
Early failure of the tissue engineered porcine heart valve SYNERGRAFT™ in pediatric patients
Simon, P. (2003) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(03)00094-0 · Cited by 624
Functional Living Trileaflet Heart Valves Grown In Vitro
Hoerstrup, S. P., Sodian, R., Daebritz, S., Wang, J., Bacha, E. A., Martin, D. P., Moran, A. M., Guleserian, K. J., Sperling, J. S., Kaushal, S., et al. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_3.iii-44 · Cited by 595
Biological factors affecting long-term results of valvular heterografts
Carpentier, A., Lemaigre, G., Robert, L., Carpentier, S., Dubost, C., & Gerbode, F. (1969) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)42561-0 · Cited by 546
ANDERSEN, H. R., KNUDSEN, L. L., & HASENKAM, J. M. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060238 · Cited by 491
Fluid Mechanics of Heart Valves
Yoganathan, A. P., He, Z., & Casey Jones, S. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140111 · Cited by 389
Self-citationFibrin gel – advantages of a new scaffold in cardiovascular tissue engineering
Jockenhoevel, S., Zund, G., Hoerstrup, S. P., Chalabi, K., Sachweh, J. S., Demircan, L., Messmer, B. J., & Turina, M. (2001) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(01)00624-8 · Cited by 362
Early In Vivo Experience With Tissue-Engineered Trileaflet Heart Valves
Sodian, R., Hoerstrup, S. P., Sperling, J. S., Daebritz, S., Martin, D. P., Moran, A. M., Kim, B. S., Schoen, F. J., Vacanti, J. P., & Mayer, J. E. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_3.iii-22 · Cited by 330
Will heart valve tissue engineering change the world?
Yacoub, M. H., & Takkenberg, J. J. M. (2005) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio0112 · Cited by 310
Percutaneous insertion of the pulmonary valve
Bonhoeffer, P., Boudjemline, Y., Qureshi, S. A., Le Bidois, J., Iserin, L., Acar, P., Merckx, J., Kachaner, J., & Sidi, D. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01822-3 · Cited by 307
Tissue-engineered heart valves. Autologous valve leaflet replacement study in a lamb model.
Shinoka, T., Ma, P. X., Shum‐Tim, D., Breuer, C. K., Cusick, R. A., Zünd, G., Langer, R., Vacanti, J. P., & Mayer, J. E. (1996) · PubMed · Cited by 246
Lattice Boltzmann simulation of solid particles suspended in fluid
Aidun, C. K., & Lu, Y. (1995) · Journal of Statistical Physics · doi:10.1007/bf02179967 · Cited by 196
Transpecies heart valve transplant: advanced studies of a bioengineered xeno-autograft
Goldstein, S., Clarke, D. R., Walsh, S. P., Black, K. S., & O’Brien, M. F. (2000) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)01812-9 · Cited by 130
Taylor, P. M., Allen, S. P., Dreger, S. A., & Yacoub, M. H. (2002) · PubMed · Cited by 111
“Shear induced platelet activation” - A critical reappraisal
Wurzinger, L. J., Opitz, R., Wolf, M., & Schmid-Schönbein, H. (1985) · Biorheology · doi:10.3233/bir-1985-22504 · Cited by 78
Mol, A., Bouten, C. V. C., Baaijens, F. F., Zünd, G., Turina, M. I., & Hoerstrup, S. P. (2004) · PubMed · Cited by 61
Ye, Q., Zünd, G., Jockenhoevel, S., Schoeberlein, A., Hoerstrup, S. P., Grünenfelder, J., Benedikt, P., & Turina, M. I. (2000) · ASAIO Journal · doi:10.1097/00002480-200011000-00014 · Cited by 53
Recent Advances in Tissue Engineering: An Invited Review
Pearson, R. G., Bhandari, R., Quirk, R. A., & Shakesheff, K. M. (2002) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v12.i1.20 · Cited by 32
Mechanical and Other Problems of Artificial Valves
Black, M. M., & Drury, P. J. (1994) · Current topics in pathology · doi:10.1007/978-3-642-76846-0_4 · Cited by 31
Cited by
Hockaday, L. A., Kang, K. H., Colangelo, N. W., Cheung, P. Y. C., Duan, B., Malone, E., Wu, J., Girardi, L. N., Bonassar, L. J., Lipson, H., et al. (2012) · Biofabrication · doi:10.1088/1758-5082/4/3/035005 · Cited by 683
Numerical Simulation of Flowing Blood Cells
Freund, J. B. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141349 · Cited by 323
Implantable Device-Related Infection
VanEpps, J. S., & Younger, J. G. (2016) · Shock · doi:10.1097/shk.0000000000000692 · Cited by 306
Perfusion decellularization of whole organs
Guyette, J. P., Gilpin, S. E., Charest, J. M., Tapias, L. F., Ren, X., & Ott, H. C. (2014) · Nature Protocols · doi:10.1038/nprot.2014.097 · Cited by 275
Transcatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Self-citation
Metadata
- Authors
- Dasi, L. P., Simon, H. A., Sucosky, P., & Yoganathan, A. P.
- Venue
- Clinical and Experimental Pharmacology and Physiology
- Publisher
- Wiley
- Published
- 2009-01-27
- Volume
- 36
- Issue
- 2
- Pages
- 225-237
- ISSN
- 0305-1870 (ISSN-L)
- 1440-1681
- OpenAlex
- W2002339668
- Cited by
- 286
- References
- 22
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.