CoChat

Validation study of a portable monitoring device for identifying OSA in a symptomatic patient population

TO, Kin‐Wang, CHAN, Wing‐Chi, CHAN, Tat‐On, TUNG, Alvin, NGAI, Jenny, NG, Susanna, CHOO, Kah‐Lin, HUI, David S. · 2009 · Respirology
Cited by 30

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background and objective: Obstructive sleep apnoea syndrome (OSAS) is a common disorder associated with early atherosclerosis, diabetes mellitus, ischaemic heart disease and cerebrovascular disease. The gold standard for confirming OSAS is based on an attended overnight polysomnography (PSG) in a sleep laboratory; however lack of health‐care resources creates long waiting times for patient access to this diagnostic test. This study evaluated the ability of a portable sleep‐monitoring device to identify patients in Hong Kong with suspected OSAS. Methods: Patients with symptoms of OSAS were invited to use the ARES (apnoea risk evaluation system) concurrently with an attended inpatient PSG. Several sets of AHI were generated by the ARES provider based on different oxygen desaturation criteria and surrogate parameters of arousal. The results were compared against PSG to determine the optimal sensitivity and specificity. Results: There were 141 patients who completed the study successfully. Results of AHI from the ARES study were presented in the order of different scoring criteria––4% oxygen desaturation alone, obstructive events with 3% oxygen desaturation and obstructive events with 1% desaturation plus surrogate arousal criteria. The sensitivity was 0.84 (95% confidence interval (CI): 0.77–0.90), 0.89 (95% CI: 0.89–0.94) and 0.97 (95% CI: 0.94–0.99), respectively. The specificity was 1, 1 and 0.63 (95% CI: 0.55–0.71), respectively. The receiver operating curve had an area of 0.96, 0.97 and 0.98, respectively. The kappa coefficient varied from 0.24 to 0.55 for agreement of severity between PSG and ARES. The likelihood ratio positive and the likelihood ratio negative were 2.61, infinity, infinity and 0.16, 0.11, 0.05, respectively, in the order of oxygen desaturation described earlier. Conclusions: The ARES device has reasonable sensitivity and specificity for diagnosing severe OSAS in symptomatic Chinese patients. There is moderate agreement between ARES and PSG in the diagnosis of severe disease, but less agreement in patients with mild/moderate disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1843.2008.01439.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
TO, K., CHAN, W., CHAN, T., TUNG, A., NGAI, J., NG, S., CHOO, K., & HUI, D. S.
Venue
Respirology
Publisher
Wiley
Published
2009-02-25
Volume
14
Issue
2
Pages
270-275
ISSN
  • 1323-7799 (ISSN-L)
  • 1440-1843
OpenAlex
W2081130941
Cited by
30
References
5
FWCI
1.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.