CoChat

Measuring tumor hypoxia with 18F-FETNIM PET in esophageal squamous cell carcinoma: a pilot clinical study: 18F-FETNIM PET esophageal SCC hypoxia

Yue, J., Yang, Y., Cabrera, A. R., Sun, X., Zhao, S., Xie, P., Zheng, J., Ma, L., Fu, Z., Yu, J. · 2012 · Diseases of the Esophagus
Cited by 49

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to evaluate hypoxia in esophageal squamous cell carcinoma (SCC) with (18)F-fluoroerythronitroimidazole positron emission tomography/computed tomography ((18)F-FETNIM PET/CT). We determined an imaging threshold for hypoxia, quantified the spatiotemporal variability of hypoxia in untreated tumor, and evaluated the ability of (18)F-FETNIM PET to predict clinical response following concurrent chemoradiotherapy (CCRT). Twenty-eight consecutive patients with inoperable SCC of the esophagus were consecutively accrued between April 2007 and June 2010. The first 10 patients received two pretreatment (18)F-FETNIM PET/CT scans on separate days. The remaining 18 patients only underwent (18)F-FETNIM PET/CT once before CCRT. The ratio of the maximum standardized uptake value (SUV(max) ) of 336 normal tissue regions (i.e. heart, lung, brain, or muscle) to the mean standardized uptake value (SUV(mean)) of the respective patient's spleen was calculated, and the imaging threshold for hypoxia defined as the level of uptake demonstrated by less than 5% of tissue regions. Among the patients with two pretreatment scans, each pair of scans was compared with respect to location and intensity of uptake to assess for baseline spatiotemporal variability. Logistic regression analysis was used to determine whether pretreatment imaging characteristics are predictive of clinical response. The mean and median ratios of the SUV(max) of tissue : SUV(mean) of spleen were nearly identical, and 95% of the ratios fell below 1.3. The mean Dice similarity coefficient for the hypoxic volumes on pretreatment PET scans acquired in the same patient on different days was 0.12 (range, 0.05-0.21). Individuals' tumor SUV(max) and SUV(mean) did not vary significantly, but on average, the geometric centers of hypoxic regions shifted 15 mm (range, 8-20 mm) from the first pretreatment scan to the second. SUV(max) was the imaging characteristic most predictive of treatment response (P= 0.041), with high SUVmax associated with poor clinical response. (18)F-FETNIM PET/CT can depict hypoxia in esophageal SCC. Prior to CCRT, tumor hypoxia demonstrates spatial variability on different days, although overall (18)F-FETNIM uptake remains similar. Baseline SUV(max) may be predictive of treatment response.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1442-2050.2011.01209.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Yue, J., Yang, Y., Cabrera, A. R., Sun, X., Zhao, S., Xie, P., Zheng, J., Ma, L., Fu, Z., & Yu, J.
Venue
Diseases of the Esophagus
Published
2011-05-19
Volume
25
Issue
1
Pages
54-61
ISSN
1120-8694 (ISSN-L)
OpenAlex
W2170533151
Cited by
49
References
1
FWCI
2.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.