CoChat

Screening for diabetic retinopathy using a non‐mydriatic retinal camera in rural Victoria

Open access
Harper, C Alex, Livingston, Patricia M., Wood, Carolyn, Jin, Cara, Lee, Sue J., Keeffe, Jill E., McCarty, Cathy A., Taylor, Hugh R. · 1998 · Australian and New Zealand Journal of Ophthalmology
Cited by 39

The DOI matches its Crossref record.

Abstract

Purpose: To develop a screening programme for the early detection of diabetic retinopathy using non‐mydriatic retinal photography. Methods: A community based screening service was offered to all people with known diabetes mellitus in selected townships in the LaTrobe and Goulburn Valleys in Victoria. At the local examination centre, basic sociodemographic information was collected as well as details of previous use of eye care services for the early detection of diabetic retinopathy. The examination included visual acuity (VA), glycosylated haemoglobin level and Polaroid photographs of each fundus using a Canon CR5‐45NM non‐mydriatic retinal camera (Canon, Tochigiken, Japan). Dilating drops were not used. Photographs were subsequently reviewed and letters were sent to all participants (with copies to their general practitioners) with recommendations for appropriate follow up. Results: A total of I 177 people with diabetes attended the screening service, which is estimated to be 40% of the total population with known diabetes in the study area. The mean age was 65 years (range 20–94 years); 559 (48%) people reported not having a dilated fundus examination within the past 2 years; 345 (29%) people had never had a dilated fundus examination. Of the 2354 eyes, 2126 (90%) of the photographs were gradable. A total of 704 people (60%) had normal VA and no evidence of diabetic retinopathy, 209 people (18%) had diabetic retinopathy, 101 people (9%) had evidence of other fundus pathology, 42 people (3%) had reduced acuity (< 6/18) in one or both eyes (with no fundus pathology evident) and 121 people (10%) had ungradable photographs in one or both eyes. Conclusions: The present study demonstrates the usefulness of a screening programme with non‐mydriatic retinal photography as an adjunct to current eye care services for the early detection of diabetic retinopathy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1442-9071.1998.tb01526.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 39

Metadata

Authors
Harper, C. A., Livingston, P. M., Wood, C., Jin, C., Lee, S. J., Keeffe, J. E., McCarty, C. A., & Taylor, H. R.
Venue
Australian and New Zealand Journal of Ophthalmology
Publisher
Wiley
Published
1998-05
Volume
26
Issue
2
Pages
117-121
ISSN
  • 0814-9763 (ISSN-L)
  • 1440-1606
OpenAlex
W2100175376
Cited by
39
References
0
FWCI
2.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Screening for diabetic retinopathy using a non‐mydriatic retinal camera in rural Victoria. https://app.cochat.ai/papers/10.1111/j.1442-9071.1998.tb01526.x
The paper
Harper, C. A., Livingston, P. M., Wood, C., Jin, C., Lee, S. J., Keeffe, J. E., McCarty, C. A., & Taylor, H. R. (1998). Screening for diabetic retinopathy using a non‐mydriatic retinal camera in rural Victoria. Australian and New Zealand Journal of Ophthalmology. https://doi.org/10.1111/j.1442-9071.1998.tb01526.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.