A noninvasive estimation of mixed venous oxygen saturation using near‐infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Summary: Background : Near‐infrared spectroscopy (NIRS) is a noninvasive optical monitor of regional cerebral oxygen saturation (rSO 2). The aim of this study was to validate the use of NIRS by cerebral oximetry in estimating invasively measured mixed venous oxygen saturation (SvO 2) in pediatric postoperative cardiac surgery patients. Methods : Twenty patients were enrolled following cardiac surgery with intraoperative placement of a pulmonary artery (PA) or superior vena cava (SVC) catheter. Five patients underwent complete biventricular repair – complete atrioventricular canal (n = 3) and other (n = 2). Fifteen patients with functional single ventricle underwent palliative procedures – bidirectional Glenn (n = 11) and Fontan (n = 4). Cerebral rSO 2 was monitored via NIRS (INVOS 5100) during cardiac surgery and 6 h postoperatively. SvO 2 was measured from blood samples obtained via an indwelling PA or SVC catheter and simultaneously correlated with rSO 2 by NIRS at five time periods: in the operating room after weaning from cardiopulmonary bypass, after sternal closure, and in the CICU at 2, 4, and 6 h after admission. Results : Each patient had five measurements (total = 100 comparisons). SvO 2 obtained via an indwelling PA or SVC catheter for all patients correlated with rSO 2 obtained via NIRS: Pearson's correlation coefficient of 0.67 (P < 0.0001) and linear regression of r2 = 0.45 (P < 0.0001). Separate linear regression of the complete biventricular repairs demonstrated an r = 0.71, r2 = 0.50 (P < 0.0001). Bland–Altman analysis showed a bias of +3.3% with a precision of 16.6% for rSO 2 as a predictor of SvO 2 for all patients. Cerebral rSO 2 was a more accurate predictor of SvO 2 in the biventricular repair patients (bias −0.3, precision 11.8%), compared with the bidirectional Glenn and Fontan patients. Conclusions : Regional cerebral oximetry via NIRS correlates with SvO 2 obtained via invasive monitoring. However, the wide limits of agreement suggest that it may not be possible to predict absolute values of SvO 2 for any given patient based solely on the noninvasive measurement of rSO 2. Near‐infrared spectroscopy, using the INVOS 5100 cerebral oximeter, could potentially be used to indicate trends in SVO 2, but more studies needs to be performed under varying clinical conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Calculating correlation coefficients with repeated observations: Part 2—correlation between subjects
Bland, J. M., & Altman, D. G. (1995) · BMJ · doi:10.1136/bmj.310.6980.633 · Cited by 1,082
Bland, J. M., & Altman, D. G. (1995) · BMJ · doi:10.1136/bmj.310.6977.446 · Cited by 1,034
Tweddell, J. S., Hoffman, G. M., & Mussatto, K. A. (2003) · ACC Current Journal Review · doi:10.1016/s1062-1458(02)01082-6 · Cited by 462
Arterial and Venous Contributions to Near-infrared Cerebral Oximetry
Watzman, H. M., Kurth, C. D., Montenegro, L. M., Rome, J., Steven, J. M., & Nicolson, S. C. (2000) · Anesthesiology · doi:10.1097/00000542-200010000-00012 · Cited by 451
Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics
MCCORMICK, P. W., STEWART, M., GOETTING, M. G., DUJOVNY, M., LEWIS, G., & AUSMAN, J. I. (1991) · Critical Care Medicine · doi:10.1097/00003246-199101000-00020 · Cited by 322
Kim, M. B., Ward, D. S., Cartwright, C. R., Kolano, J., Chlebowski, S., & Henson, L. C. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009940031063 · Cited by 244
SCHEINMAN, M. M., BROWN, M. A., & RAPAPORT, E. (1969) · Circulation · doi:10.1161/01.cir.40.2.165 · Cited by 228
Cerebral Oxygenation during Pediatric Cardiac Surgery Using Deep Hypothermic Circulatory Arrest
Kurth, D. C., Steven, J. M., & Nicolson, S. C. (1995) · Anesthesiology · doi:10.1097/00000542-199501000-00011 · Cited by 172
Cerebral near infrared spectroscopy: emitter-detector separation must be increased
Germon, T. J., Evans, P. D., Barnett, N. J., Wall, P., Manara, A. R., & Nelson, R. J. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.6.831 · Cited by 172
Hoffman, G. M., Ghanayem, N. S., Kampine, J. M., Berger, S., Mussatto, K. A., Litwin, S. B., & Tweddell, J. S. (2000) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)01772-0 · Cited by 169
Measurement of hemoglobin flow and blood flow by near-infrared spectroscopy
Edwards, A. D., Richardson, C., van der Zee, P., Elwell, C., Wyatt, J. S., Cope, M., Delpy, D. T., & Reynolds, E. O. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.4.1884 · Cited by 153
Arterial behavior and blood circulation in the brain
(1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90089-7 · Cited by 133
Local cerebral blood volume response to carbon dioxide in man.
Greenberg, J. H., Alavi, A. A., Reivich, M., Kuhl, D., & Uzzell, B. P. (1978) · Circulation Research · doi:10.1161/01.res.43.2.324 · Cited by 129
Dullenkopf, A., Frey, B., Baenziger, O., Gerber, A., & Weiss, M. (2003) · Pediatric Anesthesia · doi:10.1046/j.1460-9592.2003.01111.x · Cited by 127
Rossi, A. F., Sommer, R. J., Lotvin, A., Gross, R. P., Steinberg, L. G., Kipel, G., Golinko, R. J., & Griepp, R. B. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90293-3 · Cited by 117
Continuous monitoring of mixed venous oxygen saturation in cardiac surgery.
Jamieson, W. R. E., Turnbull, K. W., Larrieu, A. J., Dodds, W. A., Allison, J. C., & Tyers, G. F. O. (1982) · PubMed · Cited by 72
Complications of vascular catheterization in critically ill children
Smith-Wright, D. L., Green, T. P., Lock, J. E., EGAR, M., & Fuhrman, B. P. (1984) · Critical Care Medicine · doi:10.1097/00003246-198412000-00001 · Cited by 64
An Assessment of Contributions Made by Extracranial Tissues During Cerebral Oximetry
Samra, S. K., Stanley, J. C., Zelenock, G. B., & Dorje, P. (1999) · Journal of Neurosurgical Anesthesiology · doi:10.1097/00008506-199901000-00001 · Cited by 59
Cerebral oxygenation during cardiopulmonary bypass in children
Kurth, C. D., Steven, J. M., Nicolson, S. C., & Jacobs, M. L. (1997) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70401-x · Cited by 58
Cerebral Oxygenation in Children with Syncope During Head-Upright Tilt Test
Rodríguez‐Núñez, A., Couceiro, J., Alonso, C., Eirís, J., Fuster, M., Sánchez, L., & Martinón, J. M. (1997) · Pediatric Cardiology · doi:10.1007/s002469900216 · Cited by 29
Henson, L. C., Cartwright, C. R., Chlebowski, S. M., Kolano, J., & Ward, D. S. (1997) · Anesthesiology · doi:10.1097/00000542-199709001-00402 · Cited by 8
Cited by
Near-infrared spectroscopy as an index of brain and tissue oxygenation
Murkin, J. M., & Arango, M. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep299 · Cited by 877
Hypoplastic Left Heart Syndrome
Feinstein, J. A., Benson, D. W., Dubin, A. M., Cohen, M. S., Maxey, D. M., Mahle, W. T., Pahl, E., Villafañe, J., Bhatt, A. B., Peng, L. F., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.022 · Cited by 503
Marino, B. S., Tabbutt, S., MacLaren, G., Hazinski, M. F., Adatia, I., Atkins, D. L., Checchia, P. A., DeCaen, A., Fink, E. L., Hoffman, G. M., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000524 · Cited by 203
Ranucci, M., Isgrò, G., Carlucci, C., De La Torre, T., Enginoli, S., Frigiola, A., & Surgical and Clinical Outcome REsearch (SCORE) Group (2010) · Critical Care · doi:10.1186/cc9217 · Cited by 100
Metadata
- Authors
- TORTORIELLO, T. A., STAYER, S. A., MOTT, A. R., DEAN McKENZIE, E., FRASER, C. D., ANDROPOULOS, D. B., & CHANG, A. C.
- Venue
- Pediatric Anesthesia
- Publisher
- Wiley
- Published
- 2005-05-23
- Volume
- 15
- Issue
- 6
- Pages
- 495-503
- ISSN
- 1155-5645 (ISSN-L)
- 1460-9592
- OpenAlex
- W2072864447
- Cited by
- 269
- References
- 25
- FWCI
- 11.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.