LY2189265, a long‐acting glucagon‐like peptide‐1 analogue, showed a dose‐dependent effect on insulin secretion in healthy subjects
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Aim: To assess the safety, tolerability, pharmacokinetics, pharmacodynamics and potential immunogenicity of single, escalating subcutaneous injections of a once‐weekly glucagon‐like peptide‐1 analogue in healthy subjects. Methods: This phase 1, three‐period, crossover, double‐blind, placebo‐controlled study investigated single, escalating subcutaneous doses of LY2189265 (LY) ranging from 0.1 to 12 mg; approximately six subjects were randomized to each dose. Parameters of safety, including adverse events, were assessed. The pharmacokinetic profile was assessed over 14 days. Pharmacodynamic parameters (glucose and insulin concentrations) were measured following a step‐glucose infusion (day 3) and as part of an oral glucose tolerance test (OGTT) (day 5). Results: LY was generally well tolerated with some increase in gastrointestinal symptoms with escalating doses. There were small dose‐dependent increases in pulse rate with doses ≥1.0 mg and diastolic blood pressure with doses ≥3.0 mg. The half‐life of LY was approximately 90 h, with C max occurring between 24 and 48 h in most subjects. Evidence of increase in glucose‐dependent insulin secretion and suppression of serum glucose excursions were observed during an OGTT at all doses compared to placebo; no episodes of hypoglycaemia occurred. No subjects developed antibodies to LY2189265. Conclusions: LY showed an acceptable safety profile and exhibited the expected glucagon‐like peptide‐1 pharmacological effects on glucose suppression and insulin secretion with a half‐life that supports once‐weekly dosing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeFronzo, R. A., Ratner, R. E., Han, J., Kim, D. D., Fineman, M. S., & Baron, A. D. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1092 · Cited by 1,559 · cited 1×
“Overall, the AEs reported are consistent with those previously observed following administration of GLP-1 analogues [15,16].”
ResultNauck, M. A., Kleine, N., �rskov, C., Holst, J. J., Willms, B., & Creutzfeldt, W. (1993) · Diabetologia · doi:10.1007/bf00401145 · Cited by 1,092 · cited 1×
“com GLP-1 is an incretin hormone shown in humans and animals to enhance glucose-dependent insulin secretion [6,7], suppress inappropriate glucagon secretion [8] and slow gastric emptying rate [9].”
BackgroundYamamoto, H., Lee, C. E., Marcus, J. N., Williams, T. D., Overton, J. M., Lopez, M. E., Hollenberg, A. N., Baggio, L., Saper, C. B., Drucker, D. J., et al. (2002) · Journal of Clinical Investigation · doi:10.1172/jci0215595 · Cited by 429
Schmittdiel, J. A., Uratsu, C. S., Karter, A. J., Heisler, M., Subramanian, U., Mangione, C. M., & Selby, J. V. (2008) · Journal of General Internal Medicine · doi:10.1007/s11606-008-0554-8 · Cited by 239
Cited by
Glucagon-like peptide 1 (GLP-1)
Müller, T. D., Finan, B., Bloom, S. R., D'Alessio, D., Drucker, D. J., Flatt, P. R., Fritsche, A., Gribble, F., Grill, H. J., Habener, J. F., et al. (2019) · Molecular Metabolism · doi:10.1016/j.molmet.2019.09.010 · Cited by 1,868
“The resulting half-life of 90 h in humans renders the drug suitable for once weekly administration by injection (Figure 8) [901].”
BackgroundGLP-1 receptor agonists for individualized treatment of type 2 diabetes mellitus
Meier, J. J. (2012) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2012.140 · Cited by 1,311
Coskun, T., Sloop, K. W., Loghin, C., Alsina-Fernandez, J., Urva, S., Bokvist, K. B., Cui, X., Briere, D. A., Cabrera, O., Roell, W. C., et al. (2018) · Molecular Metabolism · doi:10.1016/j.molmet.2018.09.009 · Cited by 882
Dungan, K. M., Povedano, S. T., Forst, T., González, J. G. G., Atisso, C., Sealls, W., & Fahrbach, J. L. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60976-4 · Cited by 486
Gilbert, M. P., & Pratley, R. E. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00178 · Cited by 407
Metadata
- Authors
- Barrington, P., Chien, J. Y., Tibaldi, F., Showalter, H. D. H., Schneck, K., & Ellis, B.
- Venue
- Diabetes, Obesity and Metabolism
- Publisher
- Wiley
- Published
- 2011-03-24
- Volume
- 13
- Issue
- 5
- Pages
- 434-438
- ISSN
- 1462-8902 (ISSN-L)
- 1463-1326
- OpenAlex
- W1968499323
- Cited by
- 73
- References
- 4
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: LY2189265, a long‐acting glucagon‐like peptide‐1 analogue, showed a dose‐dependent effect on insulin secretion in healthy subjects. https://app.cochat.ai/papers/10.1111/j.1463-1326.2011.01365.x
- The paper
- Barrington, P., Chien, J. Y., Tibaldi, F., Showalter, H. D. H., Schneck, K., & Ellis, B. (2011). LY2189265, a long‐acting glucagon‐like peptide‐1 analogue, showed a dose‐dependent effect on insulin secretion in healthy subjects. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/j.1463-1326.2011.01365.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.