Abstract

Objectives To determine the efficacy and possible beneficial effects of the Catalyst® vacuum device (VD) in the treatment of impotence, the ischaemic state of the penis after application of a constriction ring and the origin of the blood in the corpus cavernosum after application of the VD. Patients and methods Thirty men (mean age 62 years; range 46‐76) suffering from erectile dysfunction were selected for the trial after using the VD for 2 weeks at home. Changes in penile tumescence and rigidity before, during and after using the VD were assessed using the Rigiscan® monitor. Blood gas analysis (BGA) was performed in selected patients whilst using the VD, allowing calculation of the proportional contribution of venous and arterial blood to the increase in penile volume. The efficacy of the VD was also assessed by questionnaires completed before treatment and at the 6 month follow‐up. Results Four patients were lost to follow‐up but the 26 impotent men who used the VD for 6 months were able to have sexual intercourse after using the VD. The average rigidity measured at the base and tip of the penis after application of the VD was > 80%. The duration and extent of nocturnal penile tumescence and rigidity at the start and the end of the study improved, although only one variable increased significantly. Patients reporting spontaneous morning erections showed significant improvements in total erection‐time, erection‐phase and plateau‐phase duration, effective rigidity and tumescence increase. BGA determined 30 min after applying a constriction ring showed ischaemia of the penile blood and the mean contribution of arterial and venous blood to penile blood volume was by 58 and 42%, respectively. Conclusion The efficacy of the Catalyst® vacuum device was objectively determined and the quality of the nocturnal erections improved in some patients. After application of a constriction ring an ischaemia of the penis developed. In contrast to previous reports, the increased penis volume during the application of the VD is caused not only by arterial inflow but also by venous backflow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-410x.1995.tb07392.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 107

Metadata

Authors
Bosshardt, R. J., Farwerk, R., Sikora, R., Sohn, M., & Jakse, G.
Venue
British Journal of Urology
Publisher
Wiley
Published
1995-06
Volume
75
Issue
6
Pages
786-791
ISSN
0007-1331 (ISSN-L)
OpenAlex
W2105958804
Cited by
107
References
1
FWCI
1.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Objective measurement of the effectiveness, therapeutic success and dynamic mechanisms of the vacuum device. https://app.cochat.ai/papers/10.1111/j.1464-410x.1995.tb07392.x
The paper
Bosshardt, R. J., Farwerk, R., Sikora, R., Sohn, M., & Jakse, G. (1995). Objective measurement of the effectiveness, therapeutic success and dynamic mechanisms of the vacuum device. British Journal of Urology. https://doi.org/10.1111/j.1464-410x.1995.tb07392.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.