The Short Insulin Tolerance Test for Determination of Insulin Sensitivity: A Comparison with the Euglycaemic Clamp

Akinmokun, A., Selby, P. L., Ramaiya, K., Alberti, K. G. M. M. · 1992 · Diabetic Medicine

Abstract

The glucose clamp technique is currently regarded as the standard test for measuring insulin sensitivity against which other methods are compared but is unsuitable for routine screening of patients outside a hospital base. There is thus a need for a simpler test to measure insulin sensitivity. We have therefore compared the glucose disappearance rate KITT in the first 15 min of the insulin tolerance test (ITT) with the M and M/I values derived from the standard euglycaemic clamp in nine normal subjects and eight subjects with Type 2 (non‐insulin dependent) diabetes mellitus and coexisting obesity. All subjects underwent the ITT and euglycaemic clamp in random order. Nine subjects later had a repeat ITT to determine the reproducibility of the test. In the ITT, 0.1 U kg−1 body weight, human Actrapid insulin was given as an IV bolus and simultaneous arterialized and venous blood samples were obtained every minute for 15 min. The first order rate constant for the disappearance of glucose KITT over the period 3–15 min was taken as a measure of insulin sensitivity. The euglycaemic clamp was performed with an insulin infusion of 50 mU kg−1 h−1 for 120 min and a variable rate glucose infusion to maintain blood glucose concentration at 0.5 mmol I−1 below fasting level to minimize the effect of endogenous insulin secretion. The ratio of the mean rate of glucose infused (M, μmol kg−1 min−1) to the plasma insulin over the last 30 min of the clamp was taken as a measure of tissue sensitivity to insulin (M/I) assuming endogenous glucose output was suppressed. A close correlation was found between the glucose disappearance rate KITT and M/I values derived from the ITT and euglycaemic clamp, respectively, in both the normal (r = 0.86, p < 0.01) and the diabetic subjects (r = 0.81; p < 0.01) when arterialized blood was used but correlations were not significant with the venous blood sampling. The ITT was reproducible with a CV of 6%. The results suggest that the ITT is a suitable method of assessing insulin sensitivity and will be particularly useful in epidemiological studies, although the requirement for arterialized blood adds a measure of complexity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-5491.1992.tb01813.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 181

Metadata

Authors
Akinmokun, A., Selby, P. L., Ramaiya, K., & Alberti, K. G. M. M.
Venue
Diabetic Medicine
Publisher
Wiley
Published
1992-06
Volume
9
Issue
5
Pages
432-437
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W1985704075
Cited by
181
References
3
FWCI
4.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Short Insulin Tolerance Test for Determination of Insulin Sensitivity: A Comparison with the Euglycaemic Clamp. https://app.cochat.ai/papers/10.1111/j.1464-5491.1992.tb01813.x
The paper
Akinmokun, A., Selby, P. L., Ramaiya, K., & Alberti, K. G. M. M. (1992). The Short Insulin Tolerance Test for Determination of Insulin Sensitivity: A Comparison with the Euglycaemic Clamp. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.1992.tb01813.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.