The Short Insulin Tolerance Test for Determination of Insulin Sensitivity: A Comparison with the Euglycaemic Clamp
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The glucose clamp technique is currently regarded as the standard test for measuring insulin sensitivity against which other methods are compared but is unsuitable for routine screening of patients outside a hospital base. There is thus a need for a simpler test to measure insulin sensitivity. We have therefore compared the glucose disappearance rate KITT in the first 15 min of the insulin tolerance test (ITT) with the M and M/I values derived from the standard euglycaemic clamp in nine normal subjects and eight subjects with Type 2 (non‐insulin dependent) diabetes mellitus and coexisting obesity. All subjects underwent the ITT and euglycaemic clamp in random order. Nine subjects later had a repeat ITT to determine the reproducibility of the test. In the ITT, 0.1 U kg−1 body weight, human Actrapid insulin was given as an IV bolus and simultaneous arterialized and venous blood samples were obtained every minute for 15 min. The first order rate constant for the disappearance of glucose KITT over the period 3–15 min was taken as a measure of insulin sensitivity. The euglycaemic clamp was performed with an insulin infusion of 50 mU kg−1 h−1 for 120 min and a variable rate glucose infusion to maintain blood glucose concentration at 0.5 mmol I−1 below fasting level to minimize the effect of endogenous insulin secretion. The ratio of the mean rate of glucose infused (M, μmol kg−1 min−1) to the plasma insulin over the last 30 min of the clamp was taken as a measure of tissue sensitivity to insulin (M/I) assuming endogenous glucose output was suppressed. A close correlation was found between the glucose disappearance rate KITT and M/I values derived from the ITT and euglycaemic clamp, respectively, in both the normal (r = 0.86, p < 0.01) and the diabetic subjects (r = 0.81; p < 0.01) when arterialized blood was used but correlations were not significant with the venous blood sampling. The ITT was reproducible with a CV of 6%. The results suggest that the ITT is a suitable method of assessing insulin sensitivity and will be particularly useful in epidemiological studies, although the requirement for arterialized blood adds a measure of complexity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Role of Insulin Resistance in Human Disease
Reaven, G. M. (1988) · Diabetes · doi:10.2337/diab.37.12.1595 · Cited by 12,154
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874
The Syndromes of Insulin Resistance and Acanthosis Nigricans: Insulin-Receptor Disorders in Man
Kahn, C. R., Flier, J. S., Bar, R. S., Archer, J. A., Gorden, P., Martin, M. M., & Roth, J. (1976) · New England Journal of Medicine · doi:10.1056/nejm197604012941401 · Cited by 1,106
Insulin resistance, insulin insensitivity, and insulin unresponsiveness: A necessary distinction
Ronald Kahn, C. (1978) · Metabolism · doi:10.1016/s0026-0495(78)80007-9 · Cited by 793
Critical Variables in the Radioimmunoassay of Serum Insulin Using the Double Antibody Technic
Soeldner, J. S., & Slone, D. (1965) · Diabetes · doi:10.2337/diab.14.12.771 · Cited by 721
Glucose Intolerance and Aging: Evidence for Tissue Insensitivity to Insulin
DeFronzo, R. A. (1979) · Diabetes · doi:10.2337/diab.28.12.1095 · Cited by 595
Abumrad, N. N., Rabin, D., Diamond, M. P., & Lacy, W. W. (1981) · Metabolism · doi:10.1016/0026-0495(81)90074-3 · Cited by 567
BONORA, E., MOGHETTI, P., ZANCANARO, C., CIGOLINI, M., QUERENA, M., CACCIATORI, V., CORGNATI, A., & MUGGEO, M. (1989) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-68-2-374 · Cited by 522
Smedes, F., Kraak, J. C., & Poppe, H. (1982) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)80506-x · Cited by 427
Cited by
Thinness at birth and insulin resistance in adult life
Phillips, D. I. W., Barker, D. J. P., Hales, C. N., Hirst, S., & Osmond, C. (1994) · Diabetologia · doi:10.1007/s001250050086 · Cited by 697
The assessment of insulin resistance in man
Wallace, T. M., & Matthews, D. R. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00745.x · Cited by 677
Phillips, D. I. W., Clark, P. M., Hales, C. N., & Osmond, C. (1994) · Diabetic Medicine · doi:10.1111/j.1464-5491.1994.tb00273.x · Cited by 631
Detecting Insulin Resistance in Polycystic Ovary Syndrome: Purposes and Pitfalls
Legro, R. S., Castracane, V. D., & Kauffman, R. P. (2004) · Obstetrical & Gynecological Survey · doi:10.1097/01.ogx.0000109523.25076.e2 · Cited by 453
Insulin resistance, polycystic ovary syndrome, and type 2 diabetes mellitus
Ovalle, F., & Azziz, R. (2002) · Fertility and Sterility · doi:10.1016/s0015-0282(02)03111-4 · Cited by 428
Phillips, D. I. W., Caddy, S., Ilic, V., Fielding, B. A., Frayn, K. N., Borthwick, A. C., & Taylor, R. (1996) · Metabolism · doi:10.1016/s0026-0495(96)90260-7 · Cited by 390
Robinson, S., Kiddy, D., Gelding, S. V., Willis, D., Niththyananthan, R., Bush, A., Johnston, D. G., & Franks, S. (1993) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1993.tb02376.x · Cited by 283
Comparison of insulin sensitivity tests across a range of glucose tolerance from normal to diabetes
Hermans, M. P., Levy, J. C., Morris, R. J., & Turner, R. C. (1999) · Diabetologia · doi:10.1007/s001250051215 · Cited by 260
Evaluation of insulin sensitivity in clinical practice and in research settings
Monzillo, L. U., & Hamdy, O. (2003) · Nutrition Reviews · doi:10.1301/nr.2003.dec.397-412 · Cited by 259
“They also showed a higher CV (16 and 31%) in comparison to the conventional dose ITT (6–9% CV).(101,103,104,110) The shorter version(101,103) evolved from the notion that the counterregulatory hormone response occurs only after 20 minutes of the insulin infusion.”
ResultValidation of HOMA-IR in a model of insulin-resistance induced by a high-fat diet in Wistar rats
Antunes, L. C., Elkfury, J. L., Jornada, M. N., Foletto, K. C., & Bertoluci, M. C. (2016) · Archives of Endocrinology and Metabolism · doi:10.1590/2359-3997000000169 · Cited by 247
Luo, J., Van Yperselle, M., Rizkalla, S. W., Rossi, F., Slama, G., & Bornet, F. R. J. (2000) · The Journal of Nutrition · doi:10.1093/jn/130.6.1572 · Cited by 164
Morgan, L. M., Aspostolakou, F., Wright, J., & Gama, R. (1999) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329903600407 · Cited by 101
Murray, R. D., Wieringa, G., Lawrance, J. A., Adams, J. E., & Shalet, S. M. (2010) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2009.03754.x · Cited by 24
Borghouts, L. (2021) · doi:10.26481/dis.20000211lb · Cited by 2
Metadata
- Authors
- Akinmokun, A., Selby, P. L., Ramaiya, K., & Alberti, K. G. M. M.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 1992-06
- Volume
- 9
- Issue
- 5
- Pages
- 432-437
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W1985704075
- Cited by
- 181
- References
- 26
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.