Assessment of hypoglycaemia awareness using continuous glucose monitoring
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Aims To investigate the possibility of assessing hypoglycaemia awareness in patients with Type 1 diabetes using continuous glucose monitoring. Methods Twenty patients with Type 1 diabetes were investigated. Ten patients with Type 1 diabetes and strongly impaired hypoglycaemia awareness were compared with 10 patients with intact hypoglycaemia awareness regarding quality of hypoglycaemia perception (number of undetected hypoglycaemic episodes per 24 h, glucose level < 3.3 mmol/l). Hypoglycaemia detection was assessed using the event function of the Continuous Glucose Monitoring System (CGMS™; Medtronic MiniMed®, Northridge, CA, USA). Patients were instructed to enter an event upon suspecting being hypoglycaemic. Results Satisfactory CGMS performance could be achieved [mean r = 0.893 between calibration measurements and CGMS data, mean absolute difference (MAD) = 20.6%], although artefacts were observable and had to be controlled. Hypoglycaemia unaware patients showed a significantly higher total number of hypoglycaemic episodes (P < 0.05), number of undetected hypoglycaemic episodes (P < 0.01), and mean glucose levels (P < 0.05). Even in aware patients, undetected hypoglycaemia was observable. No significant differences regarding occurrence of nocturnal hypoglycaemia were observable. Conclusions The possibility of direct assessment of hypoglycaemia awareness using continuous glucose monitoring was demonstrated. Its application in clinical practice could be of use for assessing hypoglycaemia perception and evaluating the impact of treatment changes on hypoglycaemia awareness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Donnelly, L. A., Morris, A. D., Frier, B. M., Ellis, J. D., Donnan, P. T., Durrant, R., Band, M. M., Reekie, G., & Leese, G. P. (2005) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01501.x · Cited by 511
Agiostratidou, G., Anhalt, H., Ball, D., Blonde, L., Gourgari, E., Harriman, K. N., Kowalski, A. J., Madden, P., McAuliffe-Fogarty, A. H., McElwee-Malloy, M., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1624 · Cited by 397
Prevalence of impaired awareness of hypoglycaemia in adults with Type 1 diabetes
Geddes, J., Schopman, J. E., Zammitt, N. N., & Frier, B. M. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02413.x · Cited by 387
Impact of hypoglycaemia on quality of life and productivity in type 1 and type 2 diabetes
Davis, R. E., Morrissey, M., Peters, J. R., Wittrup-Jensen, K., Kennedy-Martin, T., & Currie, C. J. (2005) · Current Medical Research and Opinion · doi:10.1185/030079905x61929 · Cited by 218
Metadata
- Authors
- Kubiak, T., Hermanns, N., Schreckling, H. J., Kulzer, B., & Haak, T.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2004-02-20
- Volume
- 21
- Issue
- 5
- Pages
- 487-490
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2074422386
- Cited by
- 64
- References
- 2
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of hypoglycaemia awareness using continuous glucose monitoring. https://app.cochat.ai/papers/10.1111/j.1464-5491.2004.1136.x
- The paper
- Kubiak, T., Hermanns, N., Schreckling, H. J., Kulzer, B., & Haak, T. (2004). Assessment of hypoglycaemia awareness using continuous glucose monitoring. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.2004.1136.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.